FS3 Frame Synchronizer/Converter v1.1r1 41 www.aja.com
• If you need to revert to the previous setting (undo changes), push SELECT.
4. Push ADJUST momentarily to save and activate the new setting.
• If you want to revert to the default value, hold down ADJUST for 4 seconds.
2.3 Subnet Mask
This parameter determines the subnet mask used by the FS3 for TCP/IP
networking. Consult your network administrator about how to set this value.
Subnet Mask variable
Enter a subnet mask compatible with your LAN. This is only needed for
Static IP configurations.
If 2.1 is set to DHCP, the Subnet Mask is set by the DHCP server and
cannot be changed by the user.
If 2.1 is set to
Default Addr,
the default
Subnet Mask
is 255.255.255.0
2.4 Default Gateway
This parameter determines the gateway or router used on your LAN for TCP/IP
networking. Consult your network administrator about how to set this value.
Without a properly configured default gateway (whether you have a router/
gateway or not), the FS3 will be unable to see other FS units on the network,
although you may still be able to control this unit via a web browser. Also, without
a proper gateway defined, the discovery feature on the Network web page will
fail to list other FS units on the network.
Gateway Address variable
Enter the address of the gateway or router used to connect the FS3
to the network.
Default:
192.168.0.1
3 MAC Address (view only)
Selecting this parameter allows you to view the MAC address. The MAC address is
a unique value associated with the FS3’s internal network adapter. MAC addresses
are also known as hardware addresses or physical addresses. MAC addresses
uniquely identify an Ethernet adapter on a LAN.
MAC address format: MM:MM:MM:SS:SS:SS
The value is 12-digit hexadecimal, where the first half identifies the manufacturer
and the second half identifies the unique serial number.
4 SNMP Menu Parameters
The following parameters are used to setup the FS3 SNMP (Simple Network
Management Protocol) feature.
• 4.0 SNMP Enable
• 4.1 SNMP Trap Destination 1
• 4.2 SNMP Trap Port 1
• 4.3 SNMP Trap Destination 2
• 4.4 SNMP Trap Port 2
Refer to
for a description of SNMP and how the
FS3 supports it.
5 Power Supply Alarm
This parameter controls how the FS3 alarm responds to power supply
disconnection or failure. If the FS3 will be connected using only one power cord