FS4 Frame Synchronizer/Converter v1.1
5.1, 5.2 Power
Supply 1-2 Alarm
These parameters control how the FS4 alarm responds to a power supply disconnection
or failure. If the FS4 will be connected using only one power cord, you can suppress the
alarm, which only changes the color of the front panel LED for the disconnected power
supply.
6 Vid Format Alarm
(Single Ch only) When set to
Normal
(default), an alarm is triggered (the Channel Select
LED of that video processor [VID1 - Vid4] will light red) whenever the selected input
video signal format for that Video Processor is incompatible with the selected output
format. You can suppress the
Format Alarm
if you wish.
6.1-6.4 Vid1-4
Format Alarm
(4Ch only) Same as Vid 1 Format Alarm menu, except for Video Processors 1-4.
7 Reference Alarm
This parameter controls how the FS4 responds when the Video Processors has a format
that is incompatible with the Reference video signal. When set to
NORMAL,
the alarm
triggers (the REF LED on the FS4 front panel will light red) if the Reference signal is not
detected or is incompatible with the processor format. You can suppress the Reference
alarm is you wish.
NOTE:
For proper operation the Input reference signal must be stable and properly terminated using
a 75-ohm terminator on either the unused loop connector or the last piece of downstream
equipment to which the Ref Video is connected.
8 Hidden Menus
This parameter lets you choose whether to hide or show inactive menus.
9 Screen Saver
This parameter lets you choose the menu screen saver.
Normal (default)
Suppress
Alarm triggers if either internal power supply experiences a failure or is
disconnected from mains power.
Alarm will not be triggered by a power supply failure or disconnection
from power.
Normal (default)
Suppress
Alarm triggers if the format of the selected input video signal is
incompatible with the selected output format.
Alarm will not be triggered by a format incompatibility.
Normal (default)
Suppress
Alarm triggers if the reference signal is not detected or is
incompatible with the processor format.
Alarm will not be triggered by reference errors.
Hide Inactive (default)
Show All
Hides menus that are not in use.
Shows all menus, even those that are not in use.
On (AJA Logo) (default)
Off
System Name
AJA logo screen saver is displayed
The screen saver is not displayed.
Screen saver displays the system name.