2.1-2.8 SDI 1-8 SRC
Mode
These parameters control the use of sample rate converters for the incoming SDI
embedded audio. This setting affects all 16 embedded audio channels for that SDI input,
if present.
In
Auto
mode, normal PCM audio passes through the Sample Rate Converters and gets
converted, as appropriate. If any of the active input signals are non-PCM the SRC is
turned off for all audio inputs.
2.9 AES SRC Mode
These parameters control the use of sample rate converters for the incoming AES audio.
This setting affects all 16 AES input channels.
NOTE:
For SRC, all AES channels must be synchronous to AES1 (channel pair 1&2), or to the lowest
numbered AES pair if AES1 is not present.
2.10 MADI BNC SRC
Mode
These parameters control the use of sample rate converters for the incoming MADI BCN
audio. This setting affects all 64 MADI BNC input channels
In
Auto
mode, normal PCM audio passes through the Sample Rate Converters and gets
converted, as appropriate. If any of the active input signals are non-PCM the SRC is
turned off for all audio inputs.
2.11 MADI Fiber SRC
Mode
These parameters control the use of sample rate converters for the incoming MADI Fiber
audio. This setting affects all 64 MADI Fiber input channels
In
Auto
mode, normal PCM audio passes through the Sample Rate Converters and gets
converted, as appropriate. If any of the active signal pairs are non-PCM the SRC is turned
off for all audio inputs.
Auto (default)
On
Off
The system decides how to handle sample rate conversion. PCM
uses SRC, compressed data doesn't use SRC.
Sample rate conversion is always performed on the inputs.
Sample rate conversion is never performed on the inputs.
Auto (default)
On
Off
The system decides how to handle sample rate conversion. PCM
uses SRC, compressed data doesn't use SRC.
Sample rate conversion is always performed on the inputs.
Sample rate conversion is never performed on the inputs.
Auto (default)
On
Off
The system decides how to handle sample rate conversion. PCM
uses SRC, compressed data doesn't use SRC.
Sample rate conversion is always performed on the inputs.
Sample rate conversion is never performed on the inputs.
Auto (default)
On
Off
The system decides how to handle sample rate conversion. PCM
uses SRC, compressed data doesn't use SRC.
Sample rate conversion is always performed on the inputs.
Sample rate conversion is never performed on the inputs.