Mini-Connect v1.0
www.aja.com
7
I/O Connections
Figure 2. Mini-Connect
Mini-Converter 1
Ethernet
Connector
USB
Configuration
Port
DC Power
Input
Power LED
Ready LED
Mini-Converter 2
Mini-Converter 3
Mini-Converter 4
Ethernet Connector
Accepts LAN connection.
READY LED
• Lights green when Mini-Connect is fully powered up and usable over the network.
• Lights amber if Mini-Connect has entered safe-boot recovery mode. In safe-boot mode
you can only configure, control, and update Mini-Connect. Attached ROIs will not
appear in the WebUI.
USB Configuration Port
Accepts USB mini connector for configuration by the eMini-Setup application.
DC Power Input
5-20 VDC power input (AJA model DWP-U-R1 included).
USB Ports 1-4
Standard USB ports for communication to up to four AJA Mini-Converters.