OG-UDC 3G-SDI Up, Down, Cross-Converter v1.0 7
www.aja.com
When the
Add 3:2 Pulldown
control has been turned on (indicated by a check
mark), and the output frame rates are not the same as the input rates of 23.98 and
24.00, the DashBoard Control System displays a yellow Card State and a yellow
Signal State with a "Pulldown Active" alarm warning.
When a signal is present and locked, the DashBoard Control System shows a
green Card State and a green Signal State under the Status tab. The SDI Signal
Type is also indicated (for example, "3G-SDI").
NOTE: Alarms always show the highest priority alarm first. When that alarm condition is
resolved, the next alarm/warning condition will display, etc.