OUT terminals:
Operating Principle
WallSwitch input terminals are connected to the grid, and the output terminals
are connected to the socket or electrical appliance/system. WallSwitch
closes/opens the electric circuit, controlling the power supply by the command
of the security system user through the
. The state of WallSwitch
contacts can be switched manually: by holding the function button for 2
seconds. To make WallSwitch react to alarm or schedule automatically, you can
con gure a scenario.
WallSwitch features a protection system against voltage surge beyond the range
of 184V – 253V or overcurrent above 13А. In this case, the power supply is
interrupted, resuming after normalizing the voltage and current values.
The maximum resistive load on the relay is 3 kW.
You can check the power usage by the electrical appliance connected via
WallSwitch through the app. There is a power consumption meter.
At low loads (up to 25 W), current and power consumption indications may be displayed
incorrectly due to hardware limitations.
Connecting to the hub
Before connecting the device:
L terminal — power supply phase terminal.
N terminal — power supply neutral terminal.
N terminal — connected device neutral output contact terminal.
L terminal — connected device phase output contact terminal.
1. Switch on the hub and check its Internet connection (the logo glows white
or green).