17
Bsp.: Batterie defekt
Current input test
finished - battery
faulty
Important!
before disconnecting the charging terminals from the battery, the displayed
parameters must be entered on the battery test sheet in accordance with the Volkswa-
gen Group testing instructions for starter batteries.
1.
After a pre-defined test time, the current input test ends and the results are shown
on the display:
-
the top half of the display shows the
results of the current input test (the
display shows DEFECT if the result
is negative)
-
the bottom half of the display shows
the relevant validation code
2.
If the battery is classed as faulty, the battery does not continue charging.
Press the Info button to retrieve the following parameters:
E.g.: charging current
E.g.: battery voltage
E.g.: set battery capacity
E.g.: battery’s ability to
accept charge expressed
as in %
E.g.: device serial number
E.g.: firmware version
E.g.: battery faulty
3 . If the terminals are disconnected from the battery in this mode, the machine reverts
to the main menu
Summary of Contents for VAS 5903
Page 2: ......
Page 8: ...VI ud_fr_ls_sv_00910 022007 ...
Page 42: ...VI ud_fr_ls_sv_01055 022007 ...
Page 46: ...IV ud_fr_ls_sv_01086 042006 ...
Page 80: ...VI ud_fr_ls_sv_01056 022007 ...
Page 84: ...IV ud_fr_ls_sv_01087 032006 ...
Page 118: ...VI ud_fr_ls_sv_01060 022007 ...
Page 152: ...VI ud_fr_ls_sv_01057 022007 ...
Page 186: ...VI ud_fr_ls_sv_01058 022007 ...
Page 220: ...VI ud_fr_ls_sv_01059 022007 ...
Page 254: ...VI ud_fr_ls_sv_01064 022007 ...
Page 288: ...VI ud_fr_ls_sv_01065 022007 ...
Page 317: ......