19
USER U/I subme-
nu (user settings
for current and
voltage)
2.
Enter password 3831:
-
Using the arrow keys, enter the correct digit in the underlined position
-
Press the info button to go to the next position
-
Repeat the process until all four digits have been entered correctly
-
Press the Start/Stop button to confirm the password is correct
1.
Access the submenu
Important!
If no selection is made within 30 seconds, the setup menu is exited automati-
cally.
3.
Access the submenu
Set main charging voltage (setting range: 12.0 - 15.5 V)
-
Press Start/Stop button
-
Display flashes. Adjust main charging voltage in 0.1 V steps
-
Press Start/Stop button to confirm setting
Set maximum charging current (Setting range: see Technical Data)
-
Press Start/Stop button
-
Display flashes. Adjust max. charging current in 0.5 A steps
-
Press Start/Stop button to confirm setting
Accessing setup
menu, overview
(continued)
After the correct password has been entered, the following parameters can be specified: