20
Set maximum external power supply (Setting range: see Technical Data)
-
Press Start/Stop button
-
Adjust external power supply in 0.5 A steps
-
Press Start/Stop button to confirm setting
USER U/I subme-
nu (user settings
for current and
voltage)
(continued)
Set conservation charging voltage (setting range: Off / 12.0 - 15.5 V)
-
Press Start/Stop button
-
Display flashes. Adjust conservation charging voltage in 0.1 V steps
-
Press Start/Stop button to confirm setting
Important!
the conservation charging voltage is only available in Charge mode. Conser-
vation charging does not take place if conservation charging is set to OFF. However, if
the battery voltage drops below 12 V, charging starts.
Set safety cut-out (setting range: 2 h - 30 h)
-
Press Start/Stop button
-
Display flashes. Adjust time in 10 min intervals
-
Press Start/Stop button to confirm setting
Important!
if charging does not end automatically after the set time has elapsed, the
safety cut-out is triggered and an error message appears on the display.
Set external power supply voltage (setting range: 12.0 - 15.5 V)
-
Press Start/Stop button
-
Adjust external power supply voltage in 0.1 V steps
-
Press Start/Stop button to confirm setting
Summary of Contents for VAS 5903
Page 2: ......
Page 8: ...VI ud_fr_ls_sv_00910 022007 ...
Page 42: ...VI ud_fr_ls_sv_01055 022007 ...
Page 46: ...IV ud_fr_ls_sv_01086 042006 ...
Page 80: ...VI ud_fr_ls_sv_01056 022007 ...
Page 84: ...IV ud_fr_ls_sv_01087 032006 ...
Page 118: ...VI ud_fr_ls_sv_01060 022007 ...
Page 152: ...VI ud_fr_ls_sv_01057 022007 ...
Page 186: ...VI ud_fr_ls_sv_01058 022007 ...
Page 220: ...VI ud_fr_ls_sv_01059 022007 ...
Page 254: ...VI ud_fr_ls_sv_01064 022007 ...
Page 288: ...VI ud_fr_ls_sv_01065 022007 ...
Page 317: ......