10
Technical data
Electrical data
input
Mains voltage
~ 230 V AC
Mains frequency
50 / 60 Hz
Mains current
max. 2.9 A eff.
Mains fuse protection
max. 16 A
Efficiency
max. 95 %
Effective power
max. 420 W
Power consumption (standby)
max. 1.7 W
Protection class
I
Maximum permitted mains impedance at the interface (PCC) to the public grid
none
EMV emission class
A
Electrical data
output
Nominal output voltage
12 V DC / 6 cells
Output voltage range
2 V – 16.8 V DC
Output current
30 A at 13.5 V DC
Battery return current
< 1 mA
Mechanical data
Cooling
Convection
Dimensions l x w x h
270 x 168 x 100 mm
Weight (without cable)
2.4 kg
Environmental
conditions
Operating temperature
-20 °C - +40 °C
Storage temperature
-40 °C - +85 °C
Climate class
B
Degree of protection, horizontal position
IP40
Degree of protection, vertical position
IP44
Standards
Shock, IEC 60068-2-27 (sine 10-150 Hz,1.5 h / axis)
Push, IEC 60068-2-29 (1000 impacts of 25 g / axis)
Vibration, IEC 60068-2-64 (5 g, 5-500 Hz, 1h 40 min, 3 axes)
EN 60335-1
EN 60335-2-29
EN 61000-3-2
EN 61000-6-2
(EN 61000-4-2, EN 61000-4-3, EN 61000-4-4)
(EN 61000-4-5, EN 61000-4-6, EN 61000-4-11)
EN 61000-6-4
(Class A)