1- Warnings

-The  unit  should  be  installed  in  a  place  protected  from  vibrations, 

water and corrosive gases, where the ambient temperature does not 
exceed the value indicated in the technical data.

-For the unit to operate correctly, use only the probes supplied by AKO.
-For  the  reading  to  be  correct,  the  probe  should  be  used  in  a  place 

without  heat  influences  apart  from  the  temperature  you  want  to 
measure or control.

-The probe and its cable should 

NEVER

 be installed in a conduit together 

with power, control or feeder cables. 

-In the event of lengthening the NTC probe, always used shield cable and 

earth the mesh. In these cases, the maximum deviation will be 0.25 ºC 
from -40 ºC to +20 ºC (Maximum 1000 m with a minimum section of 

2

0.5 mm ). We recommend using 

AKO-15586

 cable.

-Always disconnect the power supply to do the wiring.
-The  power  circuit  should  be  equipped  with  a  switch  marked  as 

disconnecting device of the equipment of at least 2 A, 230 V, situated 
near the appliance.

-The power supply cable should be H05VV-F or H05V-K type. The gauge 

will depend on local regulations, but should in no case be less than 

2

1 mm . The electrical installation should be carried out under pipe.

-Using the logger not observing the manufacturer's instructions may 

alter the appliance safety requirements. Only probes supplied by AKO 
should be used for the appliance to operate correctly.

2- Installation

In programming, confirms the selection and saves the entered value.

N

 + 

P

 keys : 

Pressing for over 10 seconds accesses the data log 

display menu. 
Press 

N

 / 

Q

 to select the log block and press 

SET

 to access it. Press 

N

 / 

Q

 to select the log to be displayed, after 1 second the value of 

each input will be displayed, indicating the date and time of the log.

N

 + 

O

 keys : 

Pressing for over 10 seconds accesses the alarms log 

display menu.
Press 

N

 / 

Q

 to select the input to be displayed and press 

SET

. Press 

N

 / 

Q

 to select the event to be displayed (no. 1 is the most recent 

event),  after  1  second  the  value  of  each  input  will  be  displayed, 
indicating the date and time of the event.

N

 + 

Q

 keys: 

Pressing them for over 10 seconds accesses the 

programming menu.

1

2

2

2

60

41,5

94

125,5

35

ø max. 3,7

171

3

SET

Display

Temperature 

indication

Time indication

Alarm active

Communication 

with SD card

Maximum and minimum 

temperature indicator

Active event 

(digital input)

Browser

Slot for 
SD card

3- Technical specifications

Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90-240 V~ 50/60Hz
Alarm relay

. . . . . . . . . . . . . . . . . . . . . . . . .

8 A cos 

j

=1

NTC range (

AKO-14931

)

. . . . . . . . . . . . . . .

-50 ºC to 99.9 ºC

Range 4-20 mA

. . . . . .

Configurable from -100 to 900 (1000 levels)

Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,1
Accuracy class (-40 ºC to 40 ºC):

. . . . . . . . . .

±1 ºC acc/ EN 12830

Response time:

. . . . . . . . . . . . . . . . . . . . . .

< 20 seconds

Maximum relative time error: . . . . . . . . . . . . . . . . . . . . . . . . . < 0.1 %
Marked according to UNE-EN 12830

. . . . . . .

S,A,1,-40 ºC + 40 ºC

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Apt for use in storage (S)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Climatic environment type (A)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accuracy class (1)

Maximum input power

. . . . . . . . . . . . . . . . . . . . . .

8.5 VA

Working ambient temperature

. . . . . . . . . . . . . . .

0 ºC to 40 ºC

Storage ambient temperature

. . . . . . . . . . . . . .

-20 ºC to 60 ºC

Degree of protection

. . . . . . . . . . . . . . . . . . . . . . . .

IP40

Double insulation between power supply, secondary circuit and relay 

output.
Installation category

. . . . . . . . . . . . . . . . .

II acc/ EN 61010-1

Pollution degree

. . . . . . . . . . . . . . . . . . .

II acc/ EN 61010-1

Maintenance of date and time without power supply

. . .

Up to 2 days

Internal buzzer

. . . . . . . . . . . . . . . . . . . . . .

70dB at 30 cm

SD cards accepted

. . . . . . . . . . . . . . . .

SD/SDHC (FAT / FAT32)

4- Wiring

5- Operation

Key function

key

cording to parameter P50).

:

 A short press displays the maximum value reached in the last 

24h, and the time when all the active inputs were reached.
In the programming menu it allows scrolling around the different levels, 
or during the setting of a parameter, changing its value.

key:

 A short press displays the minimum value reached in the last 

24h, and the time when all the active inputs were reached.
In the programming menu it allows scrolling around the different levels, 
or during the setting of a parameter, changing its value.

key: 

A short press downloads the data of the ongoing log onto the SD 

card (if it has been inserted)

key: 

A short press downloads ALL the logged data onto the SD card (if 

it has been inserted). The save without changes, return to previous level 
or exit programming parameter appears on the programming menu.

SET 

key: 

A short press downloads the data of the last log onto the SD 

card (if it has been inserted).
Silences the acoustic alarm (ac

8 A

Gnd

Gnd

Tr+
Tr -

+15V

+15V

+15V

+

+

+

_

_

AKO-80040

AKO-80013

+

+

+

s

s

s

s

s

s

S1

S1

S1

DI1

4-20 mA

2 wires pasivo

4-20 mA

2 wires active

4-20 mA

3 wires

Digital 

inputs

Modbus

(Only 

AKO-15725

)

NTC

S2

S2

S2

DI2

1

6

6

6

6

6

2

7

7

7

7

7

3

8

8

8

8

8

4

9

9

9

9

9

5

10

1

1
12

AKO-15724 / AKO-15725

90-240 V~

50/60 Hz

MESSAGES

Error accessing the logger's internal memory

Probe 2 broken (Open, crossed circuit or probe out of range)

Input disabled
Top log reached
Bottom log reached

Probe 1 broken (Open, crossed circuit or probe out of range)

SD card not detected
Writing error in SD card

Error in access to the real time clock (RTC)

Error in the format of the SD card. It must be FAT/FAT32
The SD card is write protected
Password request

Reading information from the internal memory.
Internal memory empty

Message table

For further information, refer to the application note available in our website