1662H411 Ed.06
18
18
In1 table
In2 table
* If the DEF relay is free (
In1
=3, 6 or 9), it can be used to connect the extractor fan, configuring
o80
=1.
If the HUMID. relay is free (
In2
=5, 8, 11 or 14), it can be used to connect the extractor fan, configuring
o81
=1.
# Values marked with the # symbol are blocked due to the In1/In2 option chosen. To modify them, choose a
different In1/In2 option.
In1
Installation type (Cold regulation)
Parameters
Cold
regulation
Pump
Down
Defrost
Evaporator
fans
Pd o00 o80 I10 I11 d7
F3
0
Demo mode: it displays the temperature but does not regulate the temperature or activate relays.
1
Solenoid
No
Electric
Yes
#0
0
#2
0
0
#0
0
2
Solenoid
No
Air
Yes
#0
0
0
0
0
#1
#1
3
Solenoid
No
No
Yes
#0
0
0
0
0
#2
0
4
So compressor
Yes
Electric
Yes
#1
#1
#2
#5
#1
#0
0
5
So compressor
Yes
Air
Yes
#1
#1
0
#5
#1
#1
#1
6
So compressor
Yes
No
Yes
#1
#1
0
#5
#1
#2
0
7
So compressor
No
Electric
Yes
#0
#1
#2
0
0
#0
0
8
So compressor
No
Air
Yes
#0
#1
0
0
0
#1
#1
9
So compressor
No
No
Yes
#0
#1
0
0
0
#2
0
In2
Installation type (Moisture regulation)
Parameters
Diagram
to be
used
Humidifier
Heat provision
Dehumidifier
Extractor
fan
o10 o20 o81 I20 I21
1
ON/OFF
-
-
*
0
#0
#2
0
0
A
2
4-20 mA
-
-
*
0
#0
#2
0
0
B
3
ON/OFF
Resistors
-
*
0
#1
#2
0
0
A
4
4-20 mA
Resistors
-
*
0
#1
#2
0
0
B
5
No
Resistors
-
*
0
#1
0
0
0
A
6
ON/OFF
Hot gas
-
*
#4
#0
#2
#5
#1
A
7
4-20 mA
Hot gas
-
*
#4
#0
#2
#5
#1
B
8
No
Hot gas
-
*
#4
#0
0
#5
#1
A
9
ON/OFF
Hot gas + resistors
-
*
#4
#1
#2
#5
#1
A
10
4-20 mA
Hot gas + resistors
-
*
#4
#1
#2
#5
#1
B
11
No
Hot gas + resistors
-
*
#4
#1
0
#5
#1
A
12
ON/OFF
-
Yes
*
0
#2
#2
0
0
C
13
4-20 mA
-
Yes
*
0
#2
#2
0
0
D
14
No
-
Yes
*
0
#2
0
0
0
C