Instrucciones
GB
5981H002 Ed.01
AKO-59810
AKO-59820
AKO-59811
AKO-59821
i
Warnings
-If the device is used without adhering to the manufacturer's instructions, the device safety requirements could be compromised. Only probes supplied by AKO should
be used for the appliance to operate correctly.
-The device should be installed in a place protected from vibrations, water and corrosive gases, where the ambient temperature does not exceed the value indicated in the
technical data.
-For the reading to be correct, the probe should be used in a place without heat influences apart from the temperature you want to measure or control.
-Avoid installing the device on metal walls or near devices that may cause radio emissions.
-
AKO-59811x / 59821x
devices should
NEVER
be operated without installing the external antenna.
-This device can be fitted with any antenna provided it has a gain of less than 9.2 dBi and there is a minimum distance between it and any person or animal of more than 20 cm.
-This device must always be installed in an area where a minimum distance of 20 cm from the human body is ensured, to guarantee compliance with human exposure to
electromagnetic fields.
-Any type of antenna used with the equipment must comply with the limits established in the radio interface of the member estates and the following documents: Commission
Decision 2010/267/EU of 6 May 2010, ECC Decision (09)03 of 30 October 2009 and CEPT Report 30 of 30 October 2009.
-This device is powered by a non-rechargeable battery, if it runs out it must be replaced with the model
AKO-58030
. The dead battery cannot be disposed of with household
waste, it must be taken to a select collection point.
NEVER try to recharge the battery, perforate or hit the battery or immerse it in liquids or
dispose of the battery with fire.
3
5
5
9
8
1
0
0
2 R
EV
.0
0 2
0
1
9
AKO ELECTROMECÁNICA
, S.A.L.
Avda.
Roquetes, 30-38
08812
•
Sant Pere de Ribes.
Barcelona
•
Spain.
Tel.: +34 902 333 145
Fax: +34 938 934 054
www.ako.com
We
reserve the
right to
supply materials
which may
be slightly
different from
those described
in our
Data Sheets
. Updated
information on
our web
.
akonet.cloud
Description
Temperature and moisture monitor with built-in NBIoT communication. Logs temperature and moisture data and
transmits it to the cloud (akonet.cloud). Both the configuration and monitoring of the data are carried out in the cloud
itself.
Display and analysis of the logged data
Both the display of the logged data and the device configuration must be done in the
The portal also allows you to analyse the stored data using graphs, statistics and operating indicators. For more
information visit
Declaration of conformity
AKO Electromecánica S.A.L. hereby declares that the type of radioelectric device
AKO-598xxx
(Temperature and moisture monitor,
external NTC probe, battery and built-in NB-IoT) is in accordance with Directive 2014/53/EU.
The full text of the EU conformity declaration is available at the following Internet address:
http://help.ako.com/assets/uploads/DUEC598xxx.pdfSimplifi
Installation
Installation conditions:
Install the device away from draughts and condensation. Do not locate it close to evaporators, condensers or other items that may
produce electromagnetic noise. If it is installed in a chamber, locate it as close as possible to the door. If it is installed inside a cabinet or any other piece of
furniture, locate it as close as possible to its door.
Only
AKO-59811x /
AKO-59821x
5
1
2
36 mm
70 mm
3
Option A
Fixing by screws
Option B
Fixing by adhesive
3
.1
3
.2
3
.3
4
x2
Ø 2,8 mm
x2
+
Ø 5 mm