07/2015
Temperature Difference Controller TDC 3
Page 11 of 47
D Terminal connection diagrams
D.1 Solar with storage tank
Relay R1 and R2 are both switched on in
this variant, so e.g. a pump can be connected
to R2.
Relay R1: For speed control of
standard pumps, minimum load
20VA
D.2 Solar + Thermostat
Sensor side
max. 12 V
Mains side
230 VAC
Caution
Low voltage max. 12VAC/DC connection
in the left-hand terminal compartment!
Terminal:
Connection for:
S1 (2x)
Sensor 1 collector
S2 (2x)
Sensor 2 storage tank
S3 (2x)
Sensor 3 (optional)
The polarity of the sensors is freely selectable.
Mains voltages 230 VAC 50-60 Hz Connection
in the right-hand terminal compartment!
Terminal:
Connection for:
L
Mains phase conductor L
N
Mains neutral conductor N
R1
Pump L (speed)
N
Pump N
R2
Pump L (no speed)
N
Pump N
The PE protective conductor must be connected
to the PE metal terminal block!
Low voltage max. 12 VAC/DC connection
in the left-hand terminal compartment!
Terminal:
Connection for:
S1 (2x)
Sensor 1 collector
S2 (2x)
Sensor 2 storage tank low
S3 (2x)
Sensor 3 storage tank top
The polarity of the sensors is freely selectable.
Mains voltages 230 VAC 50-60 Hz Connection
in the right-hand terminal compartment!
Terminal:
Connection for:
L
Mains phase conductor L
N
Mains neutral conductor N
R1
Pump L (speed)
N
Pump N
R2
Thermostat function L
N
Thermostat function N
The PE protective conductor must be connected
to the PE metal terminal block!
Sensor side
max. 12 V
Mains side
230 VAC
Relay R1: For speed control of
standard pumps, minimum load
20 VA
Relay R1: For speed control of
standard pumps, minimum load 20 VA
Caution