07/2015
Temperature Difference Controller TDC 3
Page 12 of 47
D.3 Solar with bypass
Actuating direction of valve:
R2 on/valve on = bypass without storage
tank charging
D.4 Solar with return lift
Actuating direction of valve:
R2 on/valve on = path through the storage
tank
Sensor side
max. 12 V
Mains side
230 VAC
Caution
Relay R1: For speed control of
standard pumps, minimum load 20 VA
Low voltage max. 12 VAC/DC connection
in the left-hand terminal compartment!
Terminal:
Connection for:
S1 (2x)
Sensor 1 collector
S2 (2x)
Sensor 2 storage tank
S3 (2x)
Sensor 3 forward flow
The polarity of the sensors is freely selectable.
Mains voltages 230 VAC 50-60 Hz Connection
in the right-hand terminal compartment!
Terminal:
Connection for:
L
Mains phase conductor L
N
Mains neutral conductor N
R1
Pump L (speed)
N
Pump N
R2
Phase valve L
N
Bypass valve N
The PE protective conductor must be connected
to the PE metal terminal block!
Sensor side
max. 12 V
Mains side
230 VAC
Low voltage max. 12 VAC/DC con
nection
in the left-hand terminal compartment!
Terminal:
Connection for:
S1 (2x)
Sensor 1 collector
S2 (2x)
Sensor 2 storage tank
S3 (2x)
Sensor 3 heating circuit return
The polarity of the sensors is freely selectable.
Mains voltages 230 VAC 50-60 Hz Connection
in the right-hand terminal compartment!
Terminal:
Connection for:
L
Mains phase conductor L
N
Mains neutral conductor N
R1
Pump L (speed)
N
Pump N
R2
Valve L
N
Valve N
The PE protective conductor must be connected
to the PE metal terminal block!
Relay R1: For speed control of
standard pumps, minimum load 20 VA
Caution