Temperature Difference Controller TDC 3
Page 14 of 47
D.7 Solar 2 coll. (east/west)
Actuating direction of valve:
R2 on/valve on = collector with flow through
sensor 3
D.8 Solar 2 coll. 2 pumps
Relay R1: For speed control of
standard pumps, minimum load 20 VA
Caution
Low voltage max. 12 VAC/DC connection
in the left-hand terminal compartment!
Terminal:
Connection for:
S1 (2x)
Sensor 1 collector 1
S2 (2x)
Sensor 2 storage tank
S3 (2x)
Sensor 3 collector 2
The polarity of the sensors is freely selectable.
Mains voltages 230 VAC 50-60 Hz Connection
in the right-hand terminal compartment!
Terminal:
Connection for:
L
Mains phase conductor L
N
Mains neutral conductor N
R1
Pump L (speed)
N
Pump N
R2
Change-over valve L
N
Change-over valve N
The PE protective conductor must be connected
to the PE metal terminal block!
Sensor side
max. 12 V
Mains side
230 VAC
Sensor side
max. 12 V
Mains side
230 VAC
Relay R1: For speed control of
standard pumps, minimum load 20 VA
Low voltage max. 12 VAC/DC connection
in the left-hand terminal compartment!
Terminal:
Connection for:
S1 (2x)
Sensor 1 collector 1
S2 (2x)
Sensor 2 storage tank
S3 (2x)
Sensor 3 collector 2
The polarity of the sensors is freely selectable.
Mains voltages 230 VAC 50-60 Hz Connection
in the right-hand terminal compartment!
Terminal:
Connection for:
L
Mains phase conductor L
N
Mains neutral conductor N
R1
Pump (coll. 1) L (speed)
N
Pump (coll. 1) N
R2
Pump (coll. 2) L
N
Pump (coll. 2) N
The PE protective conductor must be connected
to the PE metal terminal block!
Caution