07/2015
Temperature Difference Controller TDC 3
Page 18 of 47
D.15 Solar + cooling 2
Description of cooling function see 6.4.1
D.16 Solar + cooling 3
Description of cooling function see 6.4.1
Sensor side
max. 12 V
Mains side
230 VAC
Low voltage max. 12 VAC/DC connection
in the left-hand terminal compartment!
Terminal:
Connection for:
S1 (2x)
Sensor 1 collector
S2 (2x)
Sensor 2 storage tank
S3 (2x)
Sensor 3 optional
The polarity of the sensors is freely selectable.
Mains voltages 230 VAC 50-60 Hz Connection
in the right-hand terminal compartment!
Terminal:
Connection for:
L
Mains phase conductor L
N
Mains neutral conductor N
R1
Pump L (speed)
N
Pump N (speed)
R2
Pump cooler L
N
Pump cooler N
The PE protective conductor must be
connected to the PE metal terminal block!
Relay R1: For speed control of
standard pumps, minimum load 20 VA
Caution
Sensor side
max. 12 V
Mains side
230 VAC
Relay R1: For speed control of
standard pumps, minimum load 20 VA
Low voltage max. 12 VAC/DC connection
in the left-hand terminal compartment!
Terminal:
Connection for:
S1 (2x)
Sensor 1 collector
S2 (2x)
Sensor 2 storage tank low
S3 (2x)
Sensor 3 storage tank top
The polarity of the sensors is freely selectable.
Mains voltages 230 VAC 50-60 Hz Connection
in the right-hand terminal compartment!
Terminal:
Connection for:
L
Mains phase conductor L
N
Mains neutral conductor N
R1
Pump, prim. L (speed)
N
Pump, primary N (speed)
R2
Pump cooler L
N
Pump cooler N
The PE protective conductor must be
connected to the PE metal terminal block!
Caution