background image

127639 

 

 

Style 9333 & 9335 Retrofit Kit Installation Instructions 

 

Table of Contents  

1.

 

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   2 

 

2.

 

TOOLS REQUIRED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   2 

 

3.

 

PRODUCT RATINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2 

 

4.

 

OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2 

 

5.

 

SYSTEM INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .    3 

 

5.1.

 

ELECTRICAL INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3 

 

5.2.

 

MECHANICAL INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .    3 

 

6.

 

INITIAL SETUP FOR A NEW SYSTEM – MINIMUM SETUP . . . . . . . . . . . . . . . .   3 

 

6.1.

 

ASSIGNING A VALVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4 

 

6.2.

 

CALIBRATING VALVE POSITION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   4 

 

7.

 

OPERATIONAL FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   5 

 

7.1.

 

Opening and closing the valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5 

 

 
 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for 9333

Page 1: ...TOOLS REQUIRED 2 3 PRODUCT RATINGS 2 4 OVERVIEW 2 5 SYSTEM INSTALLATION 3 5 1 ELECTRICAL INSTALLATION 3 5 2 MECHANICAL INSTALLATION 3 6 INITIAL SETUP FOR A NEW SYSTEM MINIMUM SETUP 3 6 1 ASSIGNING A VALVE 4 6 2 CALIBRATING VALVE POSITION 4 7 OPERATIONAL FEATURES 5 7 1 Opening and closing the valve 5 ...

Page 2: ... depends on valve type Weight 3 lbs 14 kg Operating Temperature 40 C 70 C Storage Temperature 40 C 85 C Ingress protection IP67 equivalent J1939 CAN networked 4 OVERVIEW The Style 9333 9335 Navigator Pro controller allows the user to control an Akron Brass electric valve It is designed to be used with an Akron Brass Swing Out valve only The Style 9333 9335 is a display interface only and does not ...

Page 3: ...into the motor driver as well as the 10 harness that runs between the motor driver and the valve controller display If the 9335 retrofit kit is used additional adapter harnesses may need to be ordered for the flow sensor or pressure transducer refer to the wiring harnesses and components chart at the end of the instructions The only modification that will need to be made to the existing wiring is ...

Page 4: ...to controller connection the display will automatically be assigned to the valve For a different system configuration refer to the Installation Operating Manual for the appropriate valve controller If the display and motor driver are not already assigned they will request that when they are powered up together for the first time When the assignment process begins either at startup or through the S...

Page 5: ...ensor After calibration is complete press the OK button to return to the Valve Setup screen 7 OPERATIONAL FEATURES The Style 9333 9335 Navigator Pro Controller has been designed to be intuitive and easy to use Once configured the operation is simple Basic operation of the controller is described below 7 1 Opening and closing the valve To open the valve using the Navigator Pro press the GREEN butto...