In order to edit the GATEWAY
address (if needed) use the keys
corresponding to Up and Down to
select GATEWAY; then press the key
corresponding to the Edt menu voice.
ENTER
U
I
P/PF
CNT
ESC
MENU
Down
Up
<
Ent
NET MASK
GATEWAY
255.255.255.0
127.0.0.1
IP ADDR
DHCP
192.168.27.1
DISABLED
Press the keys corresponding - and
+; while press the key corresponding
to the Right menu voice in order to
move to the next fi gure.
Once editing is fi nished press the
key corresponding to the Sav menu
voice in order to save the setting.
ENTER
U
I
P/PF
CNT
ESC
MENU
NET MASK
GATEWAY
255.255.255.0
127.0.0.1
IP ADDR
DHCP
192.168.27.1
DISABLED
GATEWAY
1
27 000 000 001
-
<
Sav
+
Left
Right
In order to exit from the
Confi guration menu press the Menu/
Enter key (corresponding with the <
symbol) in order to go back a level
and then press it again to go back
another level.
ENTER
U
I
P/PF
CNT
ESC
MENU
Down
Up
<
Ent
GATEWAY
DHCP
127.0.0.1
DISABLED
NET MASK
IP ADDR
255.255.255.0
192.168.27.1
ENTER
U
I
P/PF
CNT
ESC
MENU
Down
Up
<
Ent
SETUP - COM A
SETUP - MEAS A
SETUP - ETHERNET
SETUP - COM B
SETUP - MEAS B
Press the key corresponding to the
Meas menu voice in order to exit the
setup menu and return back on the
measurements display page.
ENTER
U
I
P/PF
CNT
ESC
MENU
Meas
Setup
____ net 96
SN ______
MAC ___________
FW _.__
ETHERNET
EXPBUS
DIP FUNCTION
SLAVE
MASTER *
1 Line termination resistance (120 Ohm)
OFF
ON
2 Fail safe resistance B (-)
OFF
ON
3 Fail safe resistance A (+)
OFF
ON
4 Not used
OFF
OFF
* with RS-485 Master PUK activated
1
O
N
2
3
4
1
O
N
2
3
4
LAN 10/100 ETHERNET PORT
The instrument is equipped with a Ethernet Lan 10/100 Auto-MDI/MDIX port.
For the connection can be used a data cable straight or crossover.
Note: the port is not a PoE (Power over Ethernet = device power supply via the Lan port)
type. The connection of the device to a PoE port is anyway accepted. The power supply
anyway must be always provided by an external power supplier.
DIP-SWITCH CONFIGURATION
EXPBUS PORT
Vcc
L
H
Gnd
The ExpBus port, confi gurable via Ethernet port on web pages:
- uses a multicast communication rated at 250kb/sec with collision management
- max cable length : 10 meters
- manages up to 16 modules (but technically can manage up to 126)
- uses the UTP cable, 4 wires used:
2 for the power supply at 9 Vdc
2 for the bidirectional communication
The modules will also power supply the ExpBus port
The cable must be connected in in-out modality (multidrop) as per the RS485 Bus.