Input Limits 

Function Maximum 

Input 

V DC or V AC 

1000V DC, 700V AC 

mA DC/AC 

200mA DC/AC 

A DC/AC 

20A DC/AC (30 seconds 
max every 15 minutes) 

Frequency, Resistance, 
Capacitance, Diode, 
Continuity 

250V DC/AC 

Temperature 250V 

DC/AC 

 

SAFETY SYMBOLS 

 

This symbol adjacent to another symbol, terminal or 

operating device indicates that the operator must 

refer to an explanation in the Operating Instructions 

to avoid personal injury or damage to the meter. 

This 

WARNING

 symbol indicates a potentially 

hazardous situation, which if not avoided, could 

result in death or serious injury. 

This 

CAUTION

 symbol indicates a potentially 

hazardous situation, which if not avoided, may 

result damage to the product. 

This symbol advises the user that the terminal(s) so 

marked must not be connected to a circuit point at 

which the voltage with respect to earth ground 

exceeds (in this case) 1000 VAC or VDC. 

This symbol adjacent to one or more terminals 

identifies them as being associated with ranges 

that may, in normal use, be subjected to 

particularly hazardous voltages. For maximum 

safety, the meter and its test leads should not be 

handled when these terminals are energized. 

 

CONTROLS AND JACKS 

 

 

 

 

 

 

 

 

 

 

 

WARNING 

 

 

 

CAUTION 

 

 

 

1. 

Large 2000 count Liquid Crystal Display   

With backlight and HOLD, 

, BAT symbolic signs. 

0$;

2. Function 

switch 

3.

 

COM (negative) input jack

 3 

                                                                                                           

 4 

 

Summary of Contents for AMM-1008

Page 1: ......

Page 2: ...not avoided could result in death or serious injury This CAUTION symbol indicates a potentially hazardous situation which if not avoided may result damage to the product This symbol advises the user...

Page 3: ...oF at 70 relative humidity Storage temperature 20 oC to 60 oC 4 oF to 140 oF at 80 relative humidity For inside use max height 2000m Pollution degree 2 Power One 9V battery NEDA 1604 IEC 6F22 Dimensi...

Page 4: ...ts 200 0nF 0 1nF 2 000uF 1nF 4 0 of rdg 3 dgts 200 0uF 0 1uF 4 0 of rdg 5 dgts Input Protection 250V dc or 250V ac rms Frequency Range Resolution Accuracy 20 00kHz 0 01Hz 1 5 of rdg 5 dgts Sensitivity...

Page 5: ...the function switch to the V DC position mV will appear in the display 2 Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive V jack 3...

Page 6: ...t the black test lead banana plug into the negative COM jack 2 For current measurements up to 200mA AC set the function switch to the mA range and insert the red test lead banana plug into the mA jack...

Page 7: ...ndicated in the display during the diode check is the forward voltage FREQUENCY MEASUREMENT 1 Set the function switch to the 20KHz position 2 Insert the black test lead banana plug into the negative j...

Page 8: ...voltage before removing the battery door 1 Disconnect the test leads from the meter 2 Open the battery door by loosening the screw using a Phillips head screwdriver 3 Insert the battery into battery...

Reviews: