background image

RESISTANCE MEASUREMENTS 

WARNING:

 To avoid electric shock, disconnect power 

to the unit under test and discharge all capacitors before 

taking any resistance measurements. Remove the 

batteries and unplug the line cords. 

1.

 

Set the function switch to the 



 position. 

2.

 

Insert the black test lead banana plug into the negative 

(COM) jack and the red test lead banana plug into the 

positive 

 jack. 

3.

 

Touch the test probe tips across the circuit or part under 

test. It is best to disconnect one side of the part under test 

so the rest of the circuit will not interfere with the 

resistance reading. 

4.

 

Read the resistance in the display. The display will indicate 

the proper decimal point, value and symbol.

 

CONTINUITY CHECK

 

WARNING: 

To avoid electric shock, never measure 

continuity on circuits or wires that have voltage on 

them. 

1.

 

Set the function switch to the         position. 

2.

 

Insert the black lead banana plug into the negative (-) 

jack (COM) and the red test lead banana plug into the 

positive (+) jack (

). 

3.

 

Press the      button until the      symbol appears 

in the display. 

4.

 

Touch the test probe tips to the circuit or wire you wish 

to check.   

5.

 

If the resistance is less than approximately 100

, the 

audible signal will sound. The display will also show the 

actual resistance. 

DIODE TEST 

WARNING: 

To avoid electric shock, do not test any 

diode that has voltage on it. 

1.  Set the function switch to         position. 

2.  Press the      button until the      symbol appears 

in the display. 

3.   Insert the black test lead banana plug into the negative (-) 

jack (COM) and the red test lead banana plug into the 

positive (+) jack (

). 

4.

 

  Touch the test probe tips to the diode or 

semiconductor junction you wish to test. Note the meter 

reading 

 

5.   Reverse the probe polarity by switching probe position. 

Note this reading. 

6.    The diode or junction can be evaluated as follows: 

A. If one reading shows a value and the other reading 

shows OL, the diode is good. 

B. If both readings show OL, the device is open. 

C. If both readings are very small or 0, the device is 

shorted. 

 

NOTE:

    The value indicated in the display during the diode 

check is the forward voltage. 

 

FREQUENCY MEASUREMENT

 

1.    Set the function switch to the FREQ position. 

2.   Insert the black test lead banana plug into the negative (-) 

jack (COM) and the red test lead banana plug into the 

positive (+) jack (F). 

3.    Touch the test probe tips to the circuit under test. 

4.  Read the frequency in the display. The digital reading 

will indicate the proper decimal point, symbols (Hz, kHz) 

and value. 

 

CAPACITANCE MEASUREMENTS 

WARNING:

 To avoid electric shock, disconnect power 

to the unit under test and discharge all capacitors before 

taking any capacitance measurements. Remove the 

batteries and unplug the line cords. 

1.

 

Set the function switch to the CAP position. (“nF” and a 

small value will appear in the display).   

2.

 

Insert the black test lead banana plug into the negative (-) 

jack (COM) and the red test lead banana plug into the 

positive (+) jack (CAP). 

Touch the test leads to the capacitor to be tested. The 

display will indicate the proper decimal point, value and 

symbol

 

 

 

 

 

Summary of Contents for AMM-1032

Page 1: ...the multimeter may damage the meter and expose the operator to a shock hazard Always recognize the meter voltage limits as stated on the front of the meter Never apply voltage or current to the meter...

Page 2: ...nsulation Class2 Double insulation Overvoltage category CATIII 600V CATII 1000V Display 6000 counts LCD display with function indication Polarity Automatic negative polarity indication Overrange OL ma...

Page 3: ...Maximum Input 600V dc or 600V ac rms Capacitance Auto ranging Range Resolution Accuracy 40 00nF 10pF 5 0 of rdg 50 dgts 400 0nF 0 1nF 4 000uF 1nF 40 00uF 10nF 3 0 of rdg 5 dgts 400 0uF 0 1uF 5 0 of r...

Page 4: ...AX will appear The meter will display and hold the maximum reading and will update only when a new max occurs 2 Press the MAX MIN key again and the display icon MIN will appear The meter will display...

Page 5: ...asurements set the function switch to the DC 10A position and insert the red test lead banana plug into the 10A jack 3 Remove power from the circuit under test then open up the circuit at the point wh...

Page 6: ...l appears in the display 3 Insert the black test lead banana plug into the negative jack COM and the red test lead banana plug into the positive jack 4 Touch the test probe tips to the diode or semico...

Page 7: ...l 3 Dispose of the old battery properly WARNING To avoid electric shock do not operate your meter until the battery door is in place and fastened securely BATTERY INSTALLATION WARNING To avoid electri...