TEMPERATURE MEASUREMENTS 

WARNING: 

To avoid electric shock, disconnect both 

test probes from any source of voltage before making a 

temperature measurement. 

1.

 

If you wish to measure temperature in 

o

F, set the function 

switch to the 

o

F range. If you wish to measure 

temperature in 

o

C, set the function switch to the 

o

range. 

2.

 

Insert the type K thermocouple probe black test 

lead banana plug into the negative 

COM

 jack and 

the red test lead banana plug into the positive 

Temp

 

jack.. 

3.

 

Touch the Temperature Probe head to the part whose 

temperature you wish to measure. Keep the probe 

touching the part under test until the reading stabilizes 

(about 30 seconds). 

4.

 

Read the temperature in the display. The digital reading 

will indicate the proper decimal point and value. 

WARNING: 

To avoid electric shock, be sure the 

thermocouple has been removed before changing to another 

measurement function. 

 

REPLACING THE BATTERY

 

WARNING

: To avoid electric shock, disconnect the test 

leads from any source of voltage before removing the 

battery door. 

1.

 

When the batteries become exhausted or drop below 

the operating voltage, “BAT” will appear in the 

right-hand side of the LCD display. The battery should 

be replaced. 

2.

 

Follow instructions for installing battery. See the 

Battery Installation section of this manual. 

3.    Dispose of the old battery properly.

 

WARNING: 

To avoid electric shock, do not operate your 

meter until the battery door is in place and fastened 

securely. 

BATTERY INSTALLATION 

WARNING

: To avoid electric shock, disconnect the 

test leads from any source of voltage before 

removing the battery door. 

1.

 

Disconnect the test leads from the meter. 

2.

 

Open the battery door by loosening the screw using a 

Phillips head screwdriver. 

3.

 

Insert the battery into battery holder, observing the 

correct polarity. 

4.

 

Put the battery door back in place. Secure with the two 

screws. 

WARNING: 

To avoid electric shock, do not operate the 

meter until the battery door is in place and fastened 

securely. 

NOTE

: If your meter does not work properly, check the 

fuses and battery to make sure that they are still good and 

that they are properly inserted.

 

REPLACING THE FUSES 

WARNING

: To avoid electric shock, disconnect the test 

leads from any source of voltage before removing the fuse 

door. 

1. Disconnect the test leads from the meter and any item 

under test. 

2. Open the fuse door by loosening the screw on the door 

using a Phillips head screwdriver. 

3. Remove the old fuse from its holder by gently pulling it 

out.  

3.

 

Install the new fuse into the holder. 

4.

 

Always use a fuse of the proper size and value 

(10A/250V fast blow for the 10A range). 

5.

 

Put the fuse door back in place. Insert the screw and 

tighten it securely. 

WARNING

: To avoid electric shock, do not operate your 

meter until the fuse door is in place and fastened securely.

 

 

Summary of Contents for AMM-1032

Page 1: ...the multimeter may damage the meter and expose the operator to a shock hazard Always recognize the meter voltage limits as stated on the front of the meter Never apply voltage or current to the meter...

Page 2: ...nsulation Class2 Double insulation Overvoltage category CATIII 600V CATII 1000V Display 6000 counts LCD display with function indication Polarity Automatic negative polarity indication Overrange OL ma...

Page 3: ...Maximum Input 600V dc or 600V ac rms Capacitance Auto ranging Range Resolution Accuracy 40 00nF 10pF 5 0 of rdg 50 dgts 400 0nF 0 1nF 4 000uF 1nF 40 00uF 10nF 3 0 of rdg 5 dgts 400 0uF 0 1uF 5 0 of r...

Page 4: ...AX will appear The meter will display and hold the maximum reading and will update only when a new max occurs 2 Press the MAX MIN key again and the display icon MIN will appear The meter will display...

Page 5: ...asurements set the function switch to the DC 10A position and insert the red test lead banana plug into the 10A jack 3 Remove power from the circuit under test then open up the circuit at the point wh...

Page 6: ...l appears in the display 3 Insert the black test lead banana plug into the negative jack COM and the red test lead banana plug into the positive jack 4 Touch the test probe tips to the diode or semico...

Page 7: ...l 3 Dispose of the old battery properly WARNING To avoid electric shock do not operate your meter until the battery door is in place and fastened securely BATTERY INSTALLATION WARNING To avoid electri...