background image

 

Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany 

www.AKTOBIS.de

 

Email: info@aktobis.de 

 
 
 
 

During the first operation:

 

 

As the internal piping comes into contact with moisture for the first time, it can take up to approx. 3 hours for the 
first liquid to accumulate in the collection container, depending on the humidity. 
 

Start-up time / delay:

 

 
To protect the compressor, the unit does not switch on again immediately after it has stopped operation or there 
has been an interruption in operation (e.g. emptying the condensation tank), but is first in a so-called "protection 
mode" for approx. 3 minutes, during which neither the fan nor the compressor run. The green operating light 
(running LED) also only switches on again after the protection/waiting time has elapsed. 
 

Room humidity and dehumidification performance: 

 
If you want to check the room humidity and the associated dehumidification performance with your own humidity 
meter (hygrometer), please avoid attaching this humidity meter to a wall, as this will falsify the true humidity content 
of the room air. See also the explanations under Troubleshooting !!! 
 

 

Important safety instructions: 

 

When assembling, using and cleaning, follow the operating instructions strictly and read them very carefully ! 

Supervise the dehumidifier when children are near the appliance ! 

Watch out for electricity, never walk into or insert objects into the appliance ! 

Do not place any objects on the dehumidifier ! 

Do not block the exhaust air fins of the unit and please ensure sufficient space/clearance at and around the fan 

Ensure that there is sufficient air supply to the unit, otherwise it can lead to a reduction in performance and, in 
the worst case, to overheating and/or fire ! 

Make sure that no moisture gets to the electrics of the unit ! 

Only use the recommended voltage for operating the unit ! 

Make sure that the power cable is unfolded (untied) before connecting it to the socket ! 

Make sure that the plug is cleanly and properly connected to the socket before using the appliance ! 

In case of problems or damage, always contact the manufacturer immediately and never repair it yourself ! 

Never reach near the plug or socket with wet hands ! 

Please do not use multiple sockets for operating the dehumidifier ! 

Do not repair defective or damaged cables on the unit yourself, you could get a severe electric shock ! 

Make sure that highly flammable substances (e.g. gases/oils etc.) are never in the vicinity of the unit ! 

If you are not going to use the unit for a long time, switch it off and disconnect the mains plug ! 

This appliance is not intended to be used by persons (including children) with reduced physical, sensory or 
mental capabilities, or lack of experience and/or knowledge, unless they have been given supervision or 
instruction concerning use of the appliance by a person responsible for their safety. 

Do not make any changes to the unit ! 

The dehumidifier should not be operated or stored in a room with other burning/heating appliances ! 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for WDH-520EB

Page 1: ...ccur despite careful instructions on the carton For this reason we ask you to leave the unit upright for at least 4 hours before using it for the first time 4 hours before using the unit for the first...

Page 2: ...Do not place any objects on the dehumidifier Do not block the exhaust air fins of the unit and please ensure sufficient space clearance at and around the fan Ensure that there is sufficient air suppl...

Page 3: ...rved The unit should not be stored or operated in a room with burning heating appliances or open fire Please note that the refrigerant is odourless and therefore a leak cannot be detected immediately...

Page 4: ...Aktobis AG Borsigstr 20 D 63110 Rodgau Germany www AKTOBIS de Email info aktobis de Description of the unit parts Functional description...

Page 5: ...he TIMER key Determining the remaining running time Press the TIMER button during operation to select the desired remaining running time of the dehumidifier A value between 1 12 hours can be selected...

Page 6: ...ing or uneven ground 4 4 Please always keep a distance of approx 20 cm to the wall to avoid possible overheating of the appliance Furthermore please also ensure a distance of approx 50 cm upwards when...

Page 7: ...ty air filter Fold the carrying handle upwards and then remove the air filter upwards from its holder It is best to clean the air filter carefully under lukewarm water or with a low setting suction po...

Page 8: ...at the unit inlet and of course these values only apply if the temperature and moisture content remain constant The unit rattles or makes running noises Running noises are usually caused by the air f...

Page 9: ...s Completely or partially dismantled units Conformity The dehumidifier has been tested and itself and or parts thereof have been manufactured under the following safety standards T V Rheinland GS test...

Reviews: