background image

 

Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany 

www.AKTOBIS.de

 

Email: info@aktobis.de 

 
 
Insructions for use: 
 
1.  Operational environment 
 

The maximum operating temperature should not 40°C ! 

The maximum relative humidity should not exceed 90% ! 

The unit should not be operated at altitudes higher than 1,000 metres above sea level! 

 

2.  Commissioning 
 

2.1. Set up the blower so that the air stream flows in the desired direction after switching 

on. Please note that the exhaust side of the fan is on the left-hand side when looking 
at the on/off switch and the intake side is on the right-hand side when looking at the 
on/off switch! 

 

2.2. Now insert the mains plug properly into the socket. 

 

2.3. The fan is switched on by a toggle switch (ON/OFF) located on the side of the unit. 

 

=  

OFF 

 I

 

=  

ON 

 

3.  Connection of air hoses or a dust bag

 

 

This blower has a practical plastic nozzle at the front and back. You can connect an air 
hose with a diameter of 30 cm to this either in the process (air is sucked in from a targeted 
location) or in the aftermath (air is transported to a targeted location). 
Alternatively, you have the option of attaching a dust collection bag in the exhaust air area. 
The blower can then be used as a practical air hoover.  Construction dust, for example, 
can then be collected quickly for the most part. 
A suitable dust bag is available from us as an accessory. 

 

 

 

Summary of Contents for WDH-AP11

Page 1: ...uct To ensure that you get a lot of enjoyment from this product here are a few more tips In case of any problems We hope that the unit meets your expectations If despite the greatest possible care the...

Page 2: ...e blower on moving surfaces objects or vehicles There is a risk that the unit may tip over Supervise the fan when children are near the unit Never enter or insert objects into the appliance Do not pla...

Page 3: ...mains power supply if anything seems to be wrong In this case please contact a specialist and do not attempt to repair the unit yourself Example Fan does not run during operation or fuse has blown Des...

Page 4: ...ht hand side when looking at the on off switch 2 2 Now insert the mains plug properly into the socket 2 3 The fan is switched on by a toggle switch ON OFF located on the side of the unit O OFF I ON 3...

Page 5: ...ance A professional should treat the fan shaft with lubricating oil approx every 1 500 operating hours to ensure optimum operation and a long service life of the fan 5 2 Cleaning Use a soft and damp c...