background image

                 

Address:800 S Wineville Avenue, Ontario, CA 91761,USA

Website:www.aladdin-e.com

Email: tech@aladdin-e.com

4

2.Operation

B1924-05

the fine-focus-knob to get the clear image.

When using the oil objective 100XR, a little of immersion oil must be put

between the objective and the cover glass. In addition, only when the Abbe
condenser is on the arm, the 100XR objective could be used.

2-4 Adjust condenser

For the microscope with Abbe condenser, turn the Abbe condenser to or down

to get the image brightness suitable for observacation.

2-5 Adjust diaphragm

For the microscope with disc diaphragm, turn the diaphragm to select a aperture

to get the background brightness suitable.

For the microscope with iris diaphragm, adjust the aperture of the iris diaphragm

to get the background brightness suitable.

2-6 Output digital image

Insert one end of the USB into the back port of digital observe tube, and insert

another end to PC. Then observing and processing the digital image by using
Microsee.

Run AutoRun.exe in disc to install the software and the driver, then do the steps

following with the suggestions on the interface.

Summary of Contents for B1924-05

Page 1: ...Primary Compound Microscopes Instructions Contents B1924 05 Before use 1 1 Nomenclature 2 2 Operation 3 2 1 Set the specimen slide 3 2 2 Set illumination 3 2 3 Adjust focus 3 2 4 Adjust condenser 4 2...

Page 2: ...ts on the lens surfaces 4 Before using examine to ensure the power supply voltage is consistent with the rating voltage 2 Maintenance 1 All glass surfaces must always be kept clean Fine dust on the op...

Page 3: ...ddin e com Email tech aladdin e com 2 1 Nomenclature B1924 05 Eyepiece Objective Nosepiece Stage clip Stage Rotatable diaphragm Condenser Switch Coarse focusing knob Fine focusing knob Digital monocul...

Page 4: ...ust its position by the switch of the movable specimen holder 2 2 Set illumination Insert the delivery end of standard voltage transformer into the back jack in the basement Then insert the voltage tr...

Page 5: ...ser to or down to get the image brightness suitable for observacation 2 5 Adjust diaphragm For the microscope with disc diaphragm turn the diaphragm to select a aperture to get the background brightne...

Page 6: ...ss 800 S Wineville Avenue Ontario CA 91761 USA Website www aladdin e com Email tech aladdin e com 5 2 Operation B1924 05 USB connect to PC USB connect to microscope Voltage Transformer USB Connecting...

Page 7: ...0 85 100XS 1 25 oil 45 view head 360 rotatable monocular built in 2 millions pixel CMOS chip Stand with focus system Arm stand with movable stage Specimen holder White Specimen holder Black Specimen...

Page 8: ...D illumination input DC9V 300mA four 1 25V built in chargable batteries the battery would supply the power automatically when the voltage transformer is power off Type Magnification Numerical aperture...

Page 9: ...tion magnification of objective X magnification of eyepiece 2 Field of view line field of view of the eyepiece selected magnification of the objective selected 3 N A n sin max N A is very important pa...

Page 10: ...immersion oil has accumulated on the dry objective Clean thoroughly The immersion oil is not used for oil objective 100XR Use immersion oil Air bubble in the immersion Get rid of the air bubble Use w...

Page 11: ...glass is not standard Use a standard cover glass with thickness 0 17mm 3 Can not move the slide moothly The slide is not fixed correctly Adjust it correctly The movable specimen holder is not fixed pr...

Reviews: