i30SE Direct Vent Gas-Fired Insert (Firebox Only)
A Division of Hearth Technologies Inc.
MANTEL
12"
MAX.
12"
MIN.
14"
TOP OF
UNIT
Diagram B - i30SE Clearances
F. FIREBOX ENTRY
Remove the glass by pulling out (3) Glass Retainer latches. See Figure 1. Lift the Glass Door Assembly up and remove from
the bottom retainer. See Figure 2.
Place Glass in a safe place until installation is complete.
Figure 1 - Glass Retainer Latches
Figure 2 - Glass Removal
E. CLEARANCES TO UNIT
Diagram B shows the minimum vertical and corresponding maximum horizontal dimensions of mantels or other combustible
projections above the gas fireplace of 12 inches.
When finishing the fireplace
NEVER OBSTRUCT OR MODIFY THE AIR INLET/OUTLET OPENINGS IN ANY MANNER.
While a hearth extension may be desirable for aesthetic reasons, it is not required for gas wall heaters per ANSI or
CAN/CGA testing standards.
Provide adequate accessibility clearances for servicing and proper operation.
WARNING!
FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE
ONLY PARTS SPECIFICALLY APPROVED WITH THIS APLIANCE MAY RESULT IN PROPERTY DAMAGE
AND/OR PERSONAL INJURY.