background image

PLEASE READ ALL OF THE OWNERS MANUAL AND SAFETY NOTES

IMPORTANT SAFETY NOTES:

1.

When installing your stove, particular attention should be paid to fire protection.  If this unit is not properly installed, a

house fire may result.  For your safety, follow the installation instructions and contact local building or fire officials

about restrictions and installation inspection requirements in your area.

2.

Never use gasoline or similar liquids to start a fire in this unit.  Keep all such liquids well away from stove.

3.

During operation, if any part of the stove starts to glow, the stove is in an overfired condition.  Close the air control

completely until the glowing has stopped.  OVERFIRING VOIDS WARRANTY.

4.

Cool ashes should be disposed of carefully, using a metal container.

5.

Do not burn wet or green wood.  Store wood in dry location.

6.

Do not burn garbage, treated wood, or wood with salt (driftwood, etc.).  Burning materials other than wood (including

charcoal) under adverse conditions may generate carbon monoxide in the home, resulting in illness or possible death.

7.

Do not permit creosote or soot to accumulate excessively in the chimney or inside the firebox.

8.

Check your chimney system thoroughly when installing into an existing metal or masonry chimney.  Seek professional

advice if in doubt about its condition.

9.

Do not connect this unit to a chimney flue already serving another appliance.

10. Comply with all minimum clearances to combustibles as shown in this manual for this appliance.

11. Build fire on brick firebox floor.  Do not use grates, andirons or other method to support fuel.

12. HOT WHILE IN OPERATION.  Keep children, pets, clothing and furniture away.  Contact can cause skin burns.

13. Do not connect to any air distribution duct or system.

14. RISK OF FIRE!  Do not operate with stove door or ash removal system door open.

15.   For further information refer to NFPA 211 (U.S.) or CAN/CSA-B365 (Canada).

16.

WARNING

:  WHEN ASSEMBLING A UNIBODY APPLIANCE, USE ONLY GENUINE ALADDIN HEARTH

PRODUCTS MANUFACTURED COMPONENTS.  USE OF ANY OTHER COMPONENTS WILL VOID YOUR

WARRANTY, AND COULD PRESENT A SERIOUS SAFETY HAZARD.

17.

WARNING

:  DO NOT OPERATE YOUR QUADRA-FIRE STOVE BEFORE FULLY ASSEMBLING ALL

COMPONENTS.  BURNING YOUR STOVE WITHOUT A PEDESTAL OR LEG KIT ATTACHED WILL VOID

YOUR WARRANTY, AND COULD PRESENT A SERIOUS SAFETY HAZARD.

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

QUADRA-FIRE 1900

www.aladdinhearth.com

aladdin@aladdinhearth.com

401 N. WYNNE

COLVILLE, WA  99114

North America’s Best

SAVE THESE INSTRUCTIONS

CONGRATULATIONS

—You are now the proud owner of one of the finest stoves in the world for your home —the

QUADRA-FIRE

.  Now, before installing your stove and building your first fire—record the serial number on the

warranty card.  Serial number is located on the safety label on the rear of the stove.

(Revised 10/08/1999)

   Part #250-2481/ 832-3080

Aladdin Hearth Products, warrants their wood heating appliances to the original purchaser for the lifetime of the appliance, to be free from

defects in material and workmanship.  This warranty gives you specific legal rights; you may have other rights which may vary from state

to state.

This limited Lifetime Warranty covers items such as but not limited to combustion chambers, doors, gold plating, steel baffles, manifold

tubes, and glass damaged by thermal breakage.

All parts to be replaced must be returned to an authorized Aladdin Hearth Products dealer at purchaser’s expense for inspection and

approval by Aladdin Hearth Products prior to repair or replacement.  No repair or replacement costs will be honored without approval of

Aladdin Steel Products, Inc.

This new Quadra-Fire product must be installed by a competent, authorized service contractor.  It must be installed and operated at all

times in accordance with the Installation and Operating Instructions in this manual, as well as any applicable local and national codes.

Any alteration, willful abuse, accident, or misuse of the product shall void this warranty.

Any installation, construction, transportation, or other related costs or expenses arising from defective part(s), repair, replacement, etc.,

will not be covered by this warranty, nor will Aladdin Hearth Products assume responsibility for them.  Further, Aladdin Hearth Products,

will not be responsible for any incidental, indirect, or consequential damages, except as provided by law.

All electrical components such as but not limited to blowers, wiring, speed controls, and thermodisc switches are covered by Aladdin’s

one year warranty program.

Aladdin Hearth Products, will not be responsible for any alteration to the unit which causes sooting that results in damage to the interior

or exterior of the building in which this appliance is installed.

This warranty is void if the stove has been operated in atmospheres contaminated by chlorine, fluorine, or other damaging chemicals, the

stove is subjected to prolonged periods of dampness or condensation, or there is any damage to the stove or other components due to water

or weather damage which is the result of, but not limited to, improper chimney or venting installation.

This limited Lifetime Warranty does not extend to or include paint, door gasketing, glass gasketing, firebrick, kaowool or other ceramic

insulating materials.  It does not cover installation or operational-related problems such as overfiring, use of corrosive driftwood, downdrafts

or spillage caused by environmental conditions, nearby trees, buildings, hilltops, mountains, inadequate venting or ventilation, excessive

offsets, or negative air pressures caused by mechanical systems such as furnaces, fans, clothes dryers, etc.

This limited Lifetime Warranty does not apply to venting components, hearth components or other accessories used in conjunction with

the installation of this product not manufactured by Aladdin Hearth Products.

This limited Lifetime Warranty is effective on all wood stories sold after September 1, 1996, and supersedes any and all warranties

currently in existence.

—IMPORTANT-

-

This warranty is not valid unless the warranty registration card has been properly completed in full and returned within 10 days from the

date of purchase.

FOR YOUR RECORDS:

DATE PURCHASED _________________________________     MODEL ______________________________________________

AUTHORIZED DEALER ______________________________      SERIAL ________________________________________________

Summary of Contents for Quadra Fire 1900

Page 1: ...may have other rights which may vary from state to state This limited Lifetime Warranty covers items such as but not limited to combustion chambers doors gold plating steel baffles manifold tubes and...

Page 2: ...n 14 Outside air kit installation 15 Pedestal and leg installation 16 Operating instructions Burning process 17 Combustion air system 17 Fan operating instructions 18 Operating tips 18 Burning guideli...

Page 3: ...21 Black door 832 1891 Trim door 832 0711 Gold door Leg mounting bracket for mobile home installations SERVICE PARTS 832 2530 Kaowool blanket 4 piece 832 2470 Firebox brick set 832 0550 Individual bri...

Page 4: ...26 3 4 680mm 13 3 8 340mm 2 51mm Page 25 1 Unscrew and remove the rear heat deflector 2 Attach the two S clips to the upper edge of the outer wall of the stove 3 Set top heat shield on stove and push...

Page 5: ...s indicated NOTE A 3 8 10mm minimum thickness tile or equivalent is recommended but not required NFPA 211 Use a noncombustible material with 1 25mm ventilated air space to reduce clearances However th...

Page 6: ...ed away from the heating appliance and close to the sleeping areas Follow the smoke detector manufacturer s placement and installation instructions and be sure to maintain regularly 2 A conveniently l...

Page 7: ...oof line surrounding trees prevailing winds and nearby hills can influence stove performance CONNECTION TO A MASONRY CHIMNEY 1 CHIMNEY Should the stove be connected to a masonry chimney the chimney sh...

Page 8: ...me and screws with a Phillips screwdriver turn screws counterclockwise 3 Lift glass frame pieces and glass out of the door frame 4 Lay new glass with fiberglass tape around it into the door frame maki...

Page 9: ...ainst the glass Clean glass with a nonabrasive glass cleaner such as Windex Abrasive cleaners may scratch and cause glass to crack Inspect glass regularly If you find a crack or break immediately put...

Page 10: ...ches or other combustibles are in the immediate area of the stove Be sure the room is adequately ventilated and the flue unobstructed 5 Light the paper in the stove NEVER light or rekindle stove with...

Page 11: ...r may be left on throughout the burn 3 Medium burn setting The blower should be left off until a good burn is established then turned on at a medium or high rate 4 Low burn setting The blower tends to...

Page 12: ...Fire requires three things to burn fuel air and heat So if heat is robbed from the stove during the drying stage the new load of wood has reduced the chances for a good clean burn For this reason it i...

Page 13: ...tructure that is within 10 3048mm of the chimney measured horizontally Figure 5 REMEMBER Follow the manufacturer s installation instructions and maintain the manufacturer s specified clearance distanc...

Page 14: ...ith two 20 screws supplied 2 Mount rear cover plate with four mounting screws supplied This cover will seal the pedestal floor installation or have a 4 101mm hole rear installation 3 Both kits have tw...