SYSTEM
FAN
Temperature Control
System Operation
Fan Control
Programs
Compatible Systems
LCD Display
Communication
Range
Compatible Panels
Housing
T200WLZ1 Power
T200WLZ2 Power
Dimensions
Scheduled operation, Temporary Hold
or Permanent Hold.
Off, Heating, Cooling, Auto
Heating/Cooling and Emergency Heat
for heat pumps.
Automatic or Continuous operation.
Four per day, 7-day programmable.
Gas/electric, heat pumps, single or
multi-stage depending on HVAC
module used.
Large LCD display, blue backlighting.
Wireless, 915MHz, proprietary protocol.
More than 100 feet in a structure.
eWL4 wireless zoning panel.
Molded plastic case.
Battery powered, two AA batteries.
Batteries install from front of thermostat.
Powered from the eWU4 panel with two
AA batteries used for backup.
4.95 x 4.40 x 1.05 inches (WHD)
Installer Guide
T200WLZ1 and T200WLZ2
Wireless Zoning Thermostat
Rev 9/20/12
Hold the sub-base with one hand, press the case as shown
below and pull the bottom of the thermostat from the sub-base.
Press here to release
case from sub-base.
Before Installation
Remove the Sub-base
1
The thermostat can be installed on any interior wall
approximately 5 feet above the floor. To insure accurate
reading of the space temperature, the thermostat should not be
in direct sunlight.
Install the sub-base using two #8 or #6 sheet metal screws
with wall anchors where required. Level the thermostat for
appearance.
Installing the Sub-Base
2
Slide the battery cover off and install two AA lithium or alkaline
batteries. Install the batteries with the positive terminals to the
right as shown. Replace the battery cover.
The LCD will display the time of day, the setpoint temperature
and the room temperature.
Installing the Batteries
3
Manufacturing Inc.
Phone: (800) 435-
ALAN
(2526)
Fax: (877) 333-
ALAN
(2526)
Email: alansteel@alanmfg.com
www.
ALAN
mfg