46
A-61870 July 2017
4 Maintenance
5. Re-install the pre-separation pad by aligning the slots with the holes
on the pre-separation pad and snapping it into place.
6. Close the scanner cover.
7. Go to
Maintenance
on your scanner screen display and choose
Tires
>
Reset
. See “Scanner meters” on page 37.
Replacing the pre-separation pad
1. Remove the pre-separation pad by grasping it and pulling it out of
position.
2. Discard the worn pre-separation pad.
3. Install the new pre-separation pad by aligning the slots with the
holes on the pre-separation pad and snapping it into place.
4. Go to
Maintenance
on your scanner screen display and choose
Separation pad
>
Reset
. See “Scanner meters” on page 37.