13
BOILER WATER TEMPERATURE AND ROOM TEMPERATURE
SETTINGS
Boiler can be operated with Standard Panel or Eco-panel.
Temperature Settings of Boilers Operated with Standard Panel:
The user cannot adjust the room temperature, can only adjust the temperature of
the boiler water.
He adjusts the boiler water temperature in the boiler thermostat on the panel. As the
outside temperature changes, he must also change the thermostat setting.
Temperature Settings of Boilers Operated with Eco-panel:
The user determines the desired room temperatures and time program and saves
them to the eco-panel. The boiler then operates automatically depending on the
outside temperature. With the tests to be carried out in 1 or 2 weeks, it should be
determined whether the values determined at the beginning are suitable for the
conditions of the building and suitable values for building should be found.
As long as it is not changed by the user, the eco-panel works according to the
factory settings. The factory settings are as follows;
Factory Settings
User Setting
Comfort room temperature
20 °C
Economy room temperature
16 °C
Working hours at comfort temperature
06:00 - 22:00
Working hours at economy temperature
22:00 - 06:00
Heating curve (if building with radiator)
1,5
Heating curve (if building with underfloor
heating)
1,0