background image

Green LED turns OFF 

Each Output 1,2 & 3 activates for 1½ seconds 

Orange LED turns OFF 

Sounder beeps twice (memory resets and default 
values enabled) 

4.   

Close the "Request to Exit" button 

(short purple 

and pink wires). 

Keypad backlight is OFF 

Press BELL 

Sounder beeps once 

Keypad blinks 

5.   

Remove the jumper 

on the back of the keypad. 

Sounder beeps once 

Keypad backlight is OFF 

Red led is ON 

6.   

Remove power 

to the power input terminals. 

7.   

Apply power 

to the power input terminals. 

Sounder beeps once 

If the keypad encounters a problem while memory is re-
setting at step 3, the sounder will beep continuously until 
the jumper is removed and the procedure is repeated at 
step 1.  The factory default values are detailed below. 

 

Default Values 

No pre-configured user codes exist for new "out of the 
box" keypads.  Other default values include: 

 

User Code length

                                                           4 digits 

Illumination Duration 

                                            10 seconds 

Maximum Delay Between Key Presses

              10 seconds 

Auto Exit Program Mode

                                     120 seconds 

Factory Default Master Code

                                           1234 

Output Activation Duration

                                     5 seconds 

Sounder

                                                                   Always ON 

First Key Press Activates Output 3

                           Inactive 

Doorbell On Output 2

                              Inactive (if available) 

 

Enter Program Mode  

The keypad software has only two "modes"--"Normal 
Mode" and "Program Mode".  When you want to make 
changes to the keypad (enter new User Codes, etc.), you 
enter "Program Mode".  When you finish programming 
and wish to put the keypad into use, you exit Program 
Mode to enter "Normal Mode".   

 

Enter Program Mode

:  Press 

55#1234*

 
Enter Program Mode by pressing 

55#

, then press 

the 

Master Code 

of the lock that was set at the factory 

(

1234

), followed by the 

*

 key (the orange LED 

lights and the sounder beeps twice).   

 

The factory Master Code (

1234

) is basically a se-

cret passcode that allows you to enter Program Mode.  
But since all keypads leave the factory with this same 
Master Code, the factory Master Code is therefore not 
very secret--and should be changed to your own personal 
Master Code.  This way, only YOU can enter Program 
Mode and make changes to the keypad programming.   

 

Change Factory Master Code 

Although the factory Master Code can be changed at any 
time, for highest security, follow the procedure below: 

Think of a new four-digit numeric Master Code and either 
commit it to memory or write it here:  ___  ___  ___  ___.   

 

Note: 

 Only numbers zero through 9 are valid digits for 

either User Codes or the Master Code.  Keys 

*

 or 

#

 

are not allowed.  In addition, the Master Code and all User 
Codes must always be the same number of digits in 
length (3-6 digits allowed).  Therefore, if you enter Pro-
gram Mode and change this "Code Length" using Func-
tion 30, you must then remain in Program Mode and 
change the Master Code to conform to the new "Code 
Length".  At this point, however, we recommend you do 
not change the Code Length unless you are an advanced 
user. 

 

1.  

If not in already, enter Program Mode 

(press 

55#1234*

).   

Orange LED lights  - sounder beeps twice. 

2.  

Press 

31#

  

Green LED blinks once - sounder beeps once. 

3.  

Press new 4-digit Master Code 

and press 

#

.   

Green LED blinks once - sounder beeps once. 

4.  

Re-press new 4-digit Master Code 

and press 

#*

Green LED lights / sounder beeps for 1 second indi-
cating the Master Code was changed successfully.   

 

The keypad remains in Program Mode while the orange 
LED remains lit.  

Note:

  The keypad will automatically exit 

Program Mode if no keys are pressed within 120 seconds 
(2 minutes).   
 

Adding User Codes 

User Codes 

are 3-6 digit numbers the User presses into 

the keypad keys to activate one or more Outputs.  The A-
100IMWP keypad can hold up to 150 User Codes in its 
memory, thus allowing up to 150 people to possess their 
own individual User Codes.  The keypad memory associ-
ates each User Code with a 3-digit 

User Number

 listed 

from 000 to 149.  Therefore, when adding new User 
Codes, you must also select a 3-digit User Number be-
tween 000 and 149 that will be associated ("linked") with 
the new User Code.  As with the Master Code, only num-
bers zero through 9 are valid digits for User Codes (keys 

*

 or 

#

 are not allowed) and each User Code must be 

unique.   
 

1.  

If not in already, enter Program Mode

Orange LED lights  - sounder beeps twice. 

2.  

Press 

32#

  

Green LED blinks once - sounder beeps once. 

3.  

Press new 3-digit User Number 

and press 

#

.   

Green LED blinks once - sounder beeps once. 

4.  

Press new 4-digit User Code 

and press 

#

Green LED blinks once - sounder beeps once. 

5.  

Re-press new 4-digit User Code 

and press 

#*

Green LED lights / sounder beeps for 1 second indi-
cating the User Code was added successfully.   

 

Delete a User Code 

1.  

If not in already, enter Program Mode

Summary of Contents for A-100IMWP

Page 1: ...150 User Codes of 3 to 6 digits Output activation duration programmable from 01 99 seconds program 00 to select toggle mode All programming stored in non volatile EEPROM mem ory Orange LED Keypress fe...

Page 2: ...below Think of a new four digit numeric Master Code and either commit it to memory or write it here ___ ___ ___ ___ Note Only numbers zero through 9 are valid digits for either User Codes or the Mast...

Page 3: ...vation Duration Program time from 01 to 99 seconds Program 00 to select latch mode where output remains activated by the entry of a valid User Code until deactivated by the entry of a second valid Use...

Page 4: ...er G1 User Code G1 re enter User Code G1 Some examples of the 2 digits field press 12 to activate Outputs 1 and 2 press 23 to activate Outputs 2 and 3 press 13 to activate Outputs 1 and 3 press 02 to...

Page 5: ...twhile waiting for a keypress Confirmserrors Blinkswhen editing an existing User Number Orange Flashes to confirmkeypress Steady On to confirmin ProgramMode Flashes to confirmkeypress Green Confirmsac...

Page 6: ...ter User Code G1 33 Add or Edit a User Code with Output 1 Duration Press 33 G1 time 01 99 G1 User Number G1 User Code G1 re enter User Code G1 34 Delete User Code Press 34 G1 User Number G1 52 Add or...

Page 7: ...7 MOUNTING TEMPLATE The A 100IMWP is designed to be installed in its stainless mounting base The base is 1 wide and 6 tall...

Page 8: ...roduct has been repaired by others improperly installed improperly used abused altered damaged subjected to accident nuisance flood fire or acts of God or on which any serial numbers have been altered...

Reviews: