background image

AL-IME2-POE Mounting Template 

1-13/16" 

3-3/8" 

3-9/32" 

4" 

Summary of Contents for AL-IME2-POE

Page 1: ...Note Actual range varies with building construction AL IME2 POE Power Over Ethernet Gateway Installation Instructions ALARM LOCK 2017 WI2152BLF 12 17 AL RADIO LINK 900 MHz GFSK 50 Channels 10mW power output POWER Installer should use a UL or ETL Listed POE injector or a UL or ETL Listed POE switch POE Voltage 48VDC Nominal Input Voltage 5 6VAC ENVIRONMENTAL Operating Temperature 20 to 60 C 4 to 14...

Page 2: ...ling in computer closets or server rooms can negatively impact signal strength Helpful Tips In difficult installations wherein signal problems exist the use of multiple AL IME2 EXP Expand ers throughout the premises is recommended AL IME2 EXP Expanders extend the coverage area of version 2 Gateways allowing control of up to its rated maximum of 63 locks Up to 7 Expanders can be added to one versio...

Page 3: ...h the static IP address infor mation of the subnet you plan to communicate with Disconnect from the local network remove power from the Gateway Gateway will retain static IP information Re connect re apply power in the desired loca tion subnet EXPANDER GROUP DIALS Inside the Gateway are 2 rotary dials see Fig 4 These dials are used to set the Expander Group when you wish to add AL IME2 EXP Expande...

Page 4: ...e Red LED will blink slowly while searching for an IP address If the GREEN LED turns on solid for 3 seconds the Gateway received a valid IP address from the network The Yellow LED will turn on solid and the Green LED will flicker indicating the Gateway is ready for Discovery by DL Windows not config ured If the RED LED turns on solid for 3 seconds after 3 attempts to receive an IP address from the...

Page 5: ...tulations You re finished Now go to the DL WINDOWS for Networx V5 USER S GUIDE OI383 for instructions about discovering your Gate way from DL Windows Fig 6 Bottom Screw Yellow Red Transmitter On Green Gateway Status Not configured Rapid blinking flickering Idle configured 1 blink per second Lock Communication Fail 2 blinks continuously Expander Communication Fail 4 blinks continuously Receiver On ...

Page 6: ...6 NOTES ...

Page 7: ...7 AL IME2 POE Mounting Template 1 13 16 3 3 8 3 9 32 4 ...

Page 8: ...lvents or other chemi cals This warranty contains the entire warranty It is the sole warranty and any prior agreements or representations whether oral or written are either merged herein or are expressly cancelled ALARM LOCK neither assumes nor authorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warran ty or liability concerning its product...

Reviews: