can also reset the Gateway any time after the Gate-
way is powered.  Two levels of reset exist, a "Normal" 
reset and "Factory" reset, as follows: 

 
 

Normal Reset: 

 Clears Gateway memory and user 

data allowing for re-discovery by DL-Windows.  Press 
and hold the 

RESET 

button until the 

Red

 LED turns on 

solid, then release the button and the 

Green

 LED will 

start to flicker rapidly. 

 
 

Factory Reset:

  Clears Gateway memory, user data 

and configuration data (such as static IP information), 
thus returning the unit to its original factory settings.  
Press and hold the 

RESET 

button, the 

Red 

LED turns 

on solid; keep holding until the 

Yellow 

LED also turns 

on solid.  Release the button; the 

Yellow 

LED will re-

main on solid, and the 

Green

 LED will start to flicker 

rapidly, indicating a full factory reset. 

 
 

Note:

  Resetting the Gateway (Normal or Factory) 

does NOT cause the Gateway to search for a new IP 
address.  

After a reset, power cycle the Gateway to 

initiate a new IP search

.   

 
 
 
 
 
 
 
 
 
 
 
 
 
 

POWER UP 

  Connect RJ-45 Ethernet cable to the Gateway. 

 

THEN

, apply power to the Gateway using the sup-

plied transformer.  Upon connection, the Gateway au-
tomatically begins searching for a valid IP address 
from the network.   

 
 

Valid IP Address - LED Indication

  

  Upon power up, watch the 3 LEDs on the Gateway 

cover carefully to determine if the Gateway receives a 
valid IP address.  Be patient; this process 

could 

take 

up to 1 minute.  After applying power, the 

Red 

LED 

will blink slowly while searching for an IP address.   

 

If the GREEN LED turns on solid for 3 seconds

the Gateway received a valid IP address from the 
network!  The 

Yellow 

LED will turn on solid and the 

Green 

LED will flicker indicating the Gateway is 

ready for Discovery by DL-Windows (not config-
ured).   

 

If the RED LED turns on solid for 3 seconds 

(after 3 attempts to receive an IP address from the 
network), the Gateway was 

unable 

to receive a val-

id IP address from the network.  However, the 

Yel-

low 

LED will still turn on solid and the 

Green 

LED will still flicker.  

Do not confuse this with the 

above valid IP address indication

.   

 
  Refer to the flowchart for a visual representation of the 

above process: 

 
  Next, reset the Gateway as follows:   
 

  Reset the Gateway  

 

IMPORTANT:

  Before securing the Gateway hous-

ing cover, ALWAYS reset the Gateway memory, even 
if the Gateway is new "out of the box" and/or has nev-
er been used previously.   

  After initial power up, press and hold the 

RESET

 but-

ton (see below for location); continue to hold the but-
ton until the red LED turns on solid.  Now, release the 
button and the green LED will flicker rapidly.   

  Always reset the Gateway for new installations; you 

Fig. 5.  Example:  The above Expander Group dials are set to "50" 

"selection 

arrow" 

"selection 

arrow" 

 

Red LED  

blinks slowly 

(searching for IP) 

All LEDs OFF 

(briefly) 

Yellow LED ON 

Green LED Flickers 

Red LED ON 

(3 seconds) 

Red LED ON 

(several seconds) 

Connect RJ-45 / 

Apply Power 

YES 

Green LED ON 

(3 seconds) 

Received 

valid IP 

Address? 

Attempted 

search 3 

times? 

NO 

NO 

YES 

Summary of Contents for AL-IME2

Page 1: ... 50 125 Gateway Expander to Expander Clear field range 500 Typical indoor range 75 175 Note Actual AL IME2 Gateway Installation Instructions ALARM LOCK 2018 WI2210ALF 1 18 range varies with building construction AL RADIO LINK 900 MHz GFSK 50 Channels 10mW power output POWER Provided by UL Listed Class 2 Transformer Peak Supply Current 650mA Input Voltage 5 6VAC ENVIRONMENTAL Operating Temperature ...

Page 2: ...iple AL IME2 EXP Expand ers throughout the premises is recommended AL IME2 EXP Expanders extend the coverage area of version 2 Gateways allowing control of up to its rated maximum of 63 locks Up to 7 Expanders can be added to one version 2 Gateway For more information see WI2156 We recommend obtaining or creating a layout of your intended system identifying all proposed in stallation locations als...

Page 3: ...s Using DL Windows Discover and add the Gate way to an Account Configure Gateway with the static IP address infor mation of the subnet you plan to communicate with Disconnect from the local network remove power from the Gateway Gateway will retain static IP information Re connect re apply power in the desired loca tion subnet EXPANDER GROUP DIALS Inside the Gateway are 2 rotary dials see Fig 4 The...

Page 4: ... minute After applying power the Red LED will blink slowly while searching for an IP address If the GREEN LED turns on solid for 3 seconds the Gateway received a valid IP address from the network The Yellow LED will turn on solid and the Green LED will flicker indicating the Gateway is ready for Discovery by DL Windows not config ured If the RED LED turns on solid for 3 seconds after 3 attempts to...

Page 5: ...tulations You re finished Now go to the DL WINDOWS for Networx V5 USER S GUIDE OI383 for instructions about discovering your Gate way from DL Windows Fig 6 Bottom Screw Yellow Red Transmitter On Green Gateway Status Not configured Rapid blinking flickering Idle configured 1 blink per second Lock Communication Fail 2 blinks continuously Expander Communication Fail 4 blinks continuously Receiver On ...

Page 6: ...6 NOTES ...

Page 7: ...7 AL IME2 Mounting Template 1 13 16 3 3 8 3 9 32 4 ...

Page 8: ...lvents or other chemi cals This warranty contains the entire warranty It is the sole warranty and any prior agreements or representations whether oral or written are either merged herein or are expressly cancelled ALARM LOCK neither assumes nor authorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warran ty or liability concerning its product...

Reviews: