TEST DL LOCK OPERATION 
AFTER INSTALLATION 

Before testing, be sure the lock has been powered up using 
the specific "Power Up" instructions detailed in the WI1686, 
WI1687 and WI1688 programming instructions. 
 

1.    

With the key removed, the lever (or turnpiece) must be 

able rotate without retracting the latch, thus signifying 
the DL lock is disengaged. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

2.    

At the keypad, enter a valid the User Code.  For new 

locks, enter the default Master Code ("12345" for the 
DL1200ET; "123456" for the DL1300ET and 
PDL1300ET).  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

•   

For each number key pressed, verify the red LED illu-
minates. 

•   

When the last number of the Code is pressed, verify 
the green LED turns on continuously for several sec-
onds as you listen for the mechanism engage. 

•   

When the Code times out, verify the red LED flashes 
as the mechanism disengages.  

Note:

  When disen-

gaged, verify the lever (or "turnpiece") can be rotated 

without

 any movement to the latch.  

•    

At the keypad, re-enter the Code.  After the last digit of 
the Code is pressed and the lock engages, rotate the 
lever or turnpiece.  Verify the latch on the exit device 
retracts.  When the Code times out, the red LED 
flashes and the mechanism disengages.   

 

3.    Test  the  key:   

Insert the metal key, turn counterclock-

wise and operate the lever or turnpiece.  Verify the 
latch retracts. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

4.    

Turn the key clockwise and remove.  Verify the latch 

does NOT retract when the lever or turnpiece is ro-
tated. 

Test Step 2 

Test Step 1 

Latch NOT  

Retracted 

Test Step 3 

Test Step 4 

Latch NOT  

Retracted 

Latch Retracts 

Summary of Contents for DL1200ET

Page 1: ...vent schedule Keypad or PC programmable Aluminum door retrofit outside trim for Arrow S1200 S1250 series DCI 1200 1300 series Corbin Russwin ED8200 ED8400 series 33 35 and 22 series Dor O Matic 2090 series Jackson 1095 DL1200ET DL1300ET PDL1300ET NARROW STILE ACCESS LOCKS MOUNTING AND INSTALLATION INSTRUCTIONS WI1684A 10 11 345 Bayview Avenue Amityville New York 11701 For Sales and Repairs 1 800 A...

Page 2: ...r 1 requires two plastic spacers supplied For cylinders longer than 1 a collar is required Order collars from an Alarm Lock distributor Corbin Russwin HW1344 Marks HW1346 Arrow HW1348 Schlage HW1349 Cams for Standard Mortise Cylinders Sargent HW1348 Cams for IC Mortise Cylinders Best HW1343 Corbin Russwin HW1345 Medeco HW1347 Schlage HW1350 Yale HW1351 Will be supplied together with Best IC Housin...

Page 3: ...e a 1 16 hex wrench to screw the cylinder back stop screw in fully See Fig 1c The key should now only rotate counter clockwise NOTE To remove cylinder reverse steps 1a 1c Install the Lever 2 Install the lever with proper orientation for the lock door hand used Tighten the set screw using a 1 8 hex wrench see Fig 2 IMPORTANT The top of the set screw must be at or below lever surface If not check to...

Page 4: ... the Hub wall Connect Batteries 5 Loosen the 8 32 Phillips pan head screw located on the rear side of the base plate at the bottom of the lock see Fig 5 Turn counter clockwise until the battery cover slides off the housing Do not re move the screw completely 5a Plug in the battery connector Leave the battery pack and connector outside the compartment Install Lock on Door In order for the DL lock t...

Page 5: ...ut of the Receiver freely 6e Secure the DL lock to the door with four 4 through door mounting screws and two Door Plates as follows Insert a mounting screw into one of the two Door Plate holes Inside the door insert the mounting screw into the door thru holes carefully threading the mounting screw into the DL lock hous ing by hand see Fig 6e Repeat for three remain ing mounting screws Snug all fou...

Page 6: ...tinuously for several sec onds as you listen for the mechanism engage When the Code times out verify the red LED flashes as the mechanism disengages Note When disen gaged verify the lever or turnpiece can be rotated without any movement to the latch At the keypad re enter the Code After the last digit of the Code is pressed and the lock engages rotate the lever or turnpiece Verify the latch on the...

Page 7: ...7 NOTES ...

Page 8: ...n purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall ALARM LOCK be liable for an amount in excess of ALARM LOCK s original selling price of the product for any loss or damage whether direct indirect incidental consequential or otherwise arising out of any failure of the product Seller s warranty as herei...

Reviews: