6
TEST DL LOCK OPERATION
AFTER INSTALLATION
Before testing, be sure the lock has been powered up using
the specific "Power Up" instructions detailed in the WI1686,
WI1687 and WI1688 programming instructions.
1.
With the key removed, the lever (or turnpiece) must be
able rotate without retracting the latch, thus signifying
the DL lock is disengaged.
2.
At the keypad, enter a valid the User Code. For new
locks, enter the default Master Code ("12345" for the
DL1200ET; "123456" for the DL1300ET and
PDL1300ET).
•
For each number key pressed, verify the red LED illu-
minates.
•
When the last number of the Code is pressed, verify
the green LED turns on continuously for several sec-
onds as you listen for the mechanism engage.
•
When the Code times out, verify the red LED flashes
as the mechanism disengages.
Note:
When disen-
gaged, verify the lever (or "turnpiece") can be rotated
without
any movement to the latch.
•
At the keypad, re-enter the Code. After the last digit of
the Code is pressed and the lock engages, rotate the
lever or turnpiece. Verify the latch on the exit device
retracts. When the Code times out, the red LED
flashes and the mechanism disengages.
3. Test the key:
Insert the metal key, turn counterclock-
wise and operate the lever or turnpiece. Verify the
latch retracts.
4.
Turn the key clockwise and remove. Verify the latch
does NOT retract when the lever or turnpiece is ro-
tated.
Test Step 2
Test Step 1
Latch NOT
Retracted
Test Step 3
Test Step 4
Latch NOT
Retracted
Latch Retracts