background image

CONGRATULATIONS!

   

 

Your new Alarm Lock Trilogy electronic digital lock is a rugged 
double-sided entry lock of advanced design with several program-
mable features.  Three security levels are provided:  

Master 

(can 

perform ALL functions), 

Manager 

(can perform MOST functions 

plus entry), and 

Basic User 

(entry only).   

 
The lock includes 100 User Codes (consisting of Managers and 
Basic Users), plus three "one-time entry" Service Codes.  The 
Manager/Basic User Codes are organized similar to a grid--ten 
banks of ten Access Codes.   
 
Take the time to read through this guide to familiarize 
yourself with the features and operations of the lock, and 
its quick and easy programming procedures. 
 

FEATURES 

1 Master Code (all functions including entry) 

10 Manager Codes (perform SOME programming  
functions plus entry) 

90 Basic User Access Codes (Entry Only) 

3 Service Codes ("One-Time Entry" Codes) 

Two User Disable Modes: 

All User Codes Disabled Except Master Code 

All User Codes in a Bank Disabled Except Manager 
Codes 

30-Second Keypad Anti-Tamper Lockout 
(Keypad Lockout After 3 Unsuccessful User Code  
Entries) 

Programmable Relay Functions 

     (Relay may be keypad programmed to energize on any 

keypress 0-9 or on unlock). 

Locks may be pre-programmed prior to installation.  
Once installed, locks may immediately be put into use. 

Clearing all user codes only requires a simple two step 
procedure (see "Erase All Programming" on page 11). 

Trilogy 

DL5200 Programming  

Instructions

 

OI345  10/08 

© ALARM LOCK 2008 

345 Bayview Avenue 

Amityville, New York 11701 

For Sales and Repairs 1-800-ALA-LOCK 

For Technical Service 1-800-645-9440 

© ALARM LOCK 2008 

 

 

QUICK LOOKUP 

 

Wiring ............................................................... 2 

Quick Start ...................................................... 2 

Testing Codes .................................................. 3 
Manager & User Location Worksheet .............. 4 
Manager & User Location  Example ................ 5 
Programming Worksheet: Functions ............... 6 

Change Existing Master Code ...................... 7 
Add/Change Manager Codes ....................... 7 
Add/Change User Codes ............................. 7 
Deleting Codes ............................................. 7 
Disable/Enable Users ................................... 7 
Disable/Enable All ........................................ 8 
Code Location Function ............................... 8 
Next Free Code Address Locator ................. 8 
Add/Delete Service Codes  .......................... 9 
Enable/Disable Passage Mode .................... 9 
Pass Time ("Door Unlock") ........................... 9 
Disable/Enable Groups ................................ 9 
Disable/Enable Users in Bank .................... 10 
Keypress Sound Options ............................ 10 

Audible and LED Indications .......................... 11 
Battery Replacement ..................................... 11 
Erase All Programming .................................. 11 
Limited Warranty ............................................ 12 

 

DL5200  

PRIMARY SIDE  

DL5200  

SECONDARY SIDE  

Summary of Contents for DL5200

Page 1: ... Lockout After 3 Unsuccessful User Code Entries Programmable Relay Functions Relay may be keypad programmed to energize on any keypress 0 9 or on unlock Locks may be pre programmed prior to installation Once installed locks may immediately be put into use Clearing all user codes only requires a simple two step procedure see Erase All Programming on page 11 Trilogy DL5200 Programming Instructions O...

Page 2: ...e This new Master Code may consist of 3 to 6 digits however the number of digits selected determines the number required for all subsequent Manager and User Access Codes 4 Press 5 Re enter the new Master Code again to validate A 6 beep acknowledgement with a red LED will sound Wait 5 seconds for lock to re lock 6 Test the new Master Code Enter the new Master Code a beep will sound and the lock wil...

Page 3: ...es can only be deleted with the Master Code If the location User Number of the Code is unknown use the Code Location Function page 8 1 Press the new Master Code or Manager Code 2 Press press the 2 digit location number A six beep acknowledgement with a red LED will sound Wait 5 seconds for lock to re lock The User Access Code is now deleted For example if you want to delete a User Access Code loca...

Page 4: ... _ _ _ USER 62 _ _ _ _ _ _ USER 72 _ _ _ _ _ _ USER 82 _ _ _ _ _ _ USER 92 _ _ _ _ _ _ USERS USER 13 _ _ _ _ _ _ USER 23 _ _ _ _ _ _ USER 33 _ _ _ _ _ _ USER 43 _ _ _ _ _ _ USER 53 _ _ _ _ _ _ USER 63 _ _ _ _ _ _ USER 73 _ _ _ _ _ _ USER 83 _ _ _ _ _ _ USER 93 _ _ _ _ _ _ USERS USER 14 _ _ _ _ _ _ USER 24 _ _ _ _ _ _ USER 34 _ _ _ _ _ _ USER 44 _ _ _ _ _ _ USER 54 _ _ _ _ _ _ USER 64 _ _ _ _ _ _ U...

Page 5: ...e Disable Groups Function on page 9 Enter the Master Code then press 211 Manager User Location Example Manager Location Example MANAGERS MGR 10 BLANK MGR 20 BLANK MGR 30 BLANK MGR 40 BLANK MGR 50 BLANK MGR 60 MGR 70 BLANK MGR 80 BLANK MGR 90 BLANK USERS USER 11 USER 21 USER 31 USER 41 USER 51 USER 61 USER 71 USER 81 USER 91 USERS USER 12 USER 22 USER 32 USER 42 USER 52 USER 62 USER 72 USER 82 USER...

Page 6: ...ice Code 1 Press Master or Manager Code 3 0 1 Enter new Service Code _ _ _ _ _ _ Service Code 2 Press Master or Manager Code 3 0 2 Enter new Service Code _ _ _ _ _ _ Service Code 3 Press Master or Manager Code 3 0 3 Enter new Service Code _ _ _ _ _ _ Clear Service Codes Press Master or Manager Code 3 0 0 Enable Passage Mode Press Master or Manager Code 4 Disable Passage Mode Press Master or Manage...

Page 7: ...ser Row 1 9 Add Change Manager Codes __ 0 Follow the Quick Start on page 3 Note You can also add change the Manager Code in location 00 by entering the Master Code 2 then the new Manager Code __ __ __ __ __ __ __ 0 __ __ __ __ __ __ Master Code New Manager Code User Row Always zero for Managers Manager Bank Column 0 9 Deleting Manager User Codes _ _ Follow the Quick Start on page 3 __ __ __ __ __ ...

Page 8: ...from 0 9 times 3 To signify the end of the Bank number ID sequence the lock will flash both the GREEN and RED LED s and will emit a low tone 4 The lock will identify the User number by flashing the GREEN LED and beeping the sounder from 0 9 times 5 To signify the end of the Code Location function the lock will flash both the GREEN and RED LED s and will emit a low tone If no free address is found ...

Page 9: ...02 to 20 seconds The Pass Time factory default is 5 seconds NOTE The Pass Time will also determine the amount of time allowed between keypresses during programming Pass Time Door Unlock __ __ __ __ __ __ 4 __ __ Master Code Pass Time Pass Time Allows passage without the need to enter a Code into the keypad Enable Disable Passage Mode Disable Passage Mode __ __ __ __ __ __ 5 Normal Operation Master...

Page 10: ...r Code __ __ __ __ __ __ 223 Master Code High Freq KP Keypress Sound LED Default Click KP Keypress Sound LED LED Only Disable Enable Users in Bank Enter Bank number 0 9 to Enable Disable all Users in Bank Entering a disabled Code will result in an accented five beep error tone indicating the User Access Code is valid but disabled Disable Users in Bank __ __ __ __ __ __ 8 5 __ Master Manager Code B...

Page 11: ... sounder will sound for 4 seconds DL5200 Series locks use five 5 AA size 1 5 volt alkaline batteries Always replace weak batteries as soon as possible The DL5200 is equipped with special non volatile memory Thus if power is lost for ANY length of time such as discon necting the battery pack when replacing batteries or if the batteries die completely all existing User Codes are retained indefinitel...

Page 12: ...on purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall ALARM LOCK be liable for an amount in excess of ALARM LOCK s original selling price of the product for any loss or damage whether direct indirect incidental consequential or otherwise arising out of any failure of the product Seller s warranty as here...

Reviews: