6
Programming Worksheet: Functions
FUNCTION
PRESS THESE BUTTONS ON KEYPAD
Change Existing Master Code
[Enter Factory or Existing Master Code]
;1;
[Enter New Master Code
_ _ _ _ _ _
]
;
[Re-enter New Master Code
_ _ _ _ _ _
] [6 beeps = OK]
Add/Change Manager Codes (up to 10)
[Enter Master Code]
;
[Enter 2-digit Manager Location
_ _
]
;
[Enter new Manager Code
_ _ _ _ _ _
] [6 beeps = OK]
Add/Change User Codes (up to 90)
Press Master or Manager Code
;
[Enter 2-digit Location
_ _
]
;
[Enter new User Code
_ _ _ _ _ _
] [6 beeps = OK]
Deleting Manager & User Codes
Press Master or Manager Code
;
[Enter Bank Number] [Enter User Number]
;:
Disable User Number
Press Master or Manager Code
;
[Enter Bank Number] [Enter User Number]
;
Enable User Number
Press Master or Manager Code
;
[Enter Bank Number] [Enter User Number]
;
Disable All
Press Master or Manager Code
;
9
5
5
;
(
Reset with Function 944)
Enable All
Press Master or Manager Code
;
9
4
4
;
Disable Users Only
Press Master or Manager Code
;
9
5
0
;
(
Reset with Function 944)
Code Location Function
Press Master or Manager Code
;
6
;
[Enter Code to be located]
Next Free Code--Address Locator
Press Master or Manager Code
;
7
;
[Responds with Bank # and User #]
Service Code 1
Press Master or Manager Code
;
3
0
1
;
[Enter new Service Code
_ _ _ _ _ _
]
Service Code 2
Press Master or Manager Code
;
3
0
2
;
[Enter new Service Code
_ _ _ _ _ _
]
Service Code 3
Press Master or Manager Code
;
3
0
3
;
[Enter new Service Code
_ _ _ _ _ _
]
Clear Service Codes
Press Master or Manager Code
;
3
0
0
;
Enable Passage Mode
Press Master or Manager Code
;
4
;
Disable Passage Mode
Press Master or Manager Code
;
5
;
Pass Time ("Door Unlock")
Press Master Code
;
4
[Enter "02" - "20" seconds]
;
Enable Groups
Press Master Code
;
2
1
0
;
Disable Groups
Press Master Code
;
2
1
1
;
Disable Users In Bank
Press Master or Manager Code
;
8
5
[Enter Bank Number (0-9)]
;
Enable Users in Bank
Press Master or Manager Code
;
8
4
[Enter Bank Number (0-9)]
;
High Freq KP Fe LED
Press Master Code
;
2
2
0
;
Click! KP Fe LED
Press Master Code
;
2
2
2
;
LED Only
Press Master Code
;
2
2
3
;
Directions:
The Factory Master Code ("1-2-3-4-5") must first be reprogrammed as a new Master Code before any other programming
can take place. All new Access Codes must have the same number of digits as the new Master Code. Choose new Access Codes
and write them in spaces provided (in pencil) before programming the lock. 6 beeps will usually be heard after an acceptable entry.
Note:
Managers
do not
have the ability to add/delete/enable/disable Users outside their Bank, unless Groups are disabled.