background image

14 

ACCESS

 = Entry into a restricted area. 

AUDIT TRAIL

 = A date/time stamped log of previous lock 

events. 

BURGLARY CONTROL PANEL

 = Provides local alarm and 

remote communication to request security for burglary/
break-in.   

CLOCK 

REAL TIME

 

CLOCK

 = An accurate built-in clock that 

allows date/time stamping of events.  The clock can be 
slowed or speeded up to fine tune long term accuracy 
to within three minutes per year.  Programmed only 
through DL-Windows.  

 

CLOCK SETTINGS

 = Printout includes date, time, 

weekday, and clock speed.

 

DATE

 = Month, Day and Year entered as MMDDYY.  Pro-

grammed only through DL-Windows.   

DAY OF WEEK

 = Sunday through Saturday (where 1 = Sun-

day and 7 = Saturday).  Programmed only through DL-
Windows.   

DEFAULT

 = The original settings that were set at the factory; 

in other words, it is the lock's original factory condition 
when the lock was first taken out of its box.  The default 
settings are permanently encoded within the lock's fixed 
memory, and when the lock is first started, or when power 
is removed and re-applied (see pages 8-9), the original 
factory default settings are re-loaded and take effect. 

DOOR AJAR 

= The controlled door was unlocked and was 

held open for a certain duration.  If the duration is longer 
than the allowed 

Door Ajar Trip Time In Seconds

 (see 

Features 

screen, 

Options 

tab), first a log entry is re-

corded, then, if programmed, the Aux Relay engages for 
2 seconds and/or the alert Sounder (enable "

Use 

Sounder on Door Ajar

") is triggered.  

Note:

 The pro-

grammed 

Door Ajar Trip Time In Seconds

 begins after 

the programmed Pass Time ends (see "

Pass Time

"). 

DISABLE

 = Turn off. 

DOWNLOAD 

= Send data to lock. 

ENABLE

 = Turn on. 

EVENTS

 = Recorded lock activity. 

FORCED ENTRY

 = The Door Contacts detect the door was 

opened without a prior valid credential to unlock the 
PL6600 / ETPLNRX, or the door was opened without the 
inside lever first being turned (to activate the Lever Monitor 
Switch). 

GROUP 

USER GROUP

 = Defining a User to specific Groups, al-

lows User entry when the Group is allowed entry.  Pro-
grammed only through DL-Windows.  

 

GROUP 1 DISARMS BURGLAR CONTROL

 = A prox-

imity card (previously assigned to Group 1) presented to 
the lock can disarm an alarm control panel during a pre-
defined scheduled time (if the proximity card is used out-
side of the scheduled time, the alarm control panel will not 
disarm).  The alarm control panel must be armed through 
other means, must be programmed to disarm from an 
armed state only, and the zone input must be pro-
grammed for input disarming.  Programmed only through 
DL-Windows.

 

GROUP 1 ENABLES GROUP 4 USERS

 = A proximity 

card (previously assigned to Group 1) presented to the 
lock during a predefined schedule allows access to Group 
4 Users.  Programmed only through DL-Windows.  

 

GROUP 1 PUTS UNIT IN PASSAGE

 = A proximity card 

(previously assigned to Group 1) presented to the lock 
during a pre-defined schedule unlocks the lock.  Pro-
grammed only through DL-Windows.  

 

ONE TIME ONLY FOR GROUP 3 USERS 

= If selected in 

DL-Windows, allows Group 3 proximity cards to unlock 
the door one time only (thereafter their proximity card be-
comes disabled).  See OI237.

 

GUARD TOUR =

 Associated with User 298 and User 299.  A 

Guard Tour card is used to log the movement of a secu-
rity guard as he or she makes rounds from one assigned 
guard tour station to the next.  Presenting the User 299 
proximity card provides precise verification and account-
ability of a guard's movement by logging the location with 
a time and date stamp in the Event Log ("Audit Trail").  

Note: 

 Proximity cards assigned to User 298 and User 

299 are 

not 

access cards (meaning these proximity cards 

do NOT allow the security guard to pass through the 
door). 

INTERNAL RELAY FUNCTIONS

 = The PL6600/ETPLNRX 

internal relay can be programmed (via DL-Windows only) 
for one or more functions.  See page 10 for more informa-
tion. 

LOG

 = See... AUDIT TRAIL. 

PASS TIME

 = The duration in seconds that the PL6600 / 

ETPLNRX will remain unlocked after a valid proximity card 
has been presented. 

PASSAGE

 = Allow anyone to pass through the door without 

proximity cards or fob ("door is unlocked"). 

RELAY

 = Switched output allowing remote control of other 

devices.   

REMOTE INPUT

 = Allows entry into a restricted area by 

pressing a button connected to the two REMOTE INPUT 
wires (two internal white wires) by someone on the pro-
tected side of the door. 

SCHEDULE

 = A programmed operation (enable/disable, 

lock/unlock, etc.) on a specific day (Sunday through Sat-
urday) and time.  Programmed only through DL-Windows.   

SCHEDULES, QUICK

 = Any one of four most common 

types of schedules can be programmed.  Programmed 
only through DL-Windows.   

TIME

 = Hours and Minutes in the HHMM format.  Pro-

grammed only through DL-Windows.   

TIME / DATE STAMP

 = A recorded date and time that an 

event occurred. 

TIMEOUT 

= Allowing or restricting operation for a specified 

number of hours. 

UPLOAD

 = Receive data from the lock. 

USER 

= A person who has been provided with a proximity 

USER CARD for access through the door.

 

USER LOCKOUT, TOTAL

 = All Users to be locked out 

(denied access).  Proximity User Cards will not unlock the 
PL6600 / ETPLNRX.   

Glossary 

Summary of Contents for Networx ETPLNRX

Page 1: ...ARD READER ENROLLER PROXKEY KEYFOB HID HID HID CORPORATION PROXCARD DL WINDOWS PROGRAMMING SOFTWARE PL6600 ETPLNRX 345 Bayview Avenue Amityville New York 11701 For Sales and Repairs 1 800 ALA LOCK For Technical Service 1 800 645 9440 or visit us at http tech napcosecurity com Note Technical Service is for security professionals only Publicly traded on NASDAQ Symbol NSSC ALARM LOCK 2013 ...

Page 2: ...Audit Log Data may be transmitted through the radio link back to the DL Windows computer To increase security PL Series locks do not include keypads instead these models feature an HID compatible ProxCard reader In addition data can be retrieved from the lock to your PC with DL Windows software Its real time clock calendar automatically adjusts for Daylight Saving Time and allows for automated pro...

Page 3: ...e 11 Scheduling Using DL Windows 500 Scheduled Events see page 11 Automated Unlock Lock see pages 10 and 11 Enable Disable Users see page 6 for definition of User Enable Disable Groups see page 7 for definition of Group Real time clock and calendar User Access Methods ProxCard and ProxKey Keyfob Note ProxCards and ProxKey Keyfobs function identically User Features 5000 Users Service Card One Time ...

Page 4: ...LAN or corporate Intranet A Windows PC connected to this network can control and program all PL6600 ETPLNRX locks by the use of the DL Window software see OI237 and OI352 With access rights to the software one computer or several can control the software and consequently can control the devices in the system Several Gateway device models are available Wireless Wired AL IM80211 Hardwired Wireless G...

Page 5: ... in hand One additional advantage is that proximity cards and fobs cannot be dupli cated unlike ordinary metal keys Preparing to Program your Lock As the PL6600 ETPLNRX does not feature keypad buttons on its housing programming your PL6600 ETPLNRX for example adding or deleting proximity cards is allowed only using a PC that is running the computer software ap plication DL Windows The PC must be c...

Page 6: ...to suit the needs of your various installations For exam ple you can program the lock to allow Group 1 Users access ONLY during specific business hours unlock at 9AM lock at noon for lunch unlock at 1PM and lock again at 5PM every weekday In addition DL Windows makes Schedule creation much easier In DL Windows use the Schedule TimeZone screen to first create an individual block of time called a Ti...

Page 7: ...roximity card assigned to User Number 297 pos sesses the unique ability to enable the proximity card assigned to User Number 300 When proximity card 297 is presented to the lock proximity card 300 is en abled for one time use allowing passage for one time only Once used User 300 s proximity card becomes disabled For example you wish to allow one time access to a temporary worker Simply present pro...

Page 8: ...White White wires These two white Remote Input wires can be programmed as a Remote Release or for Door Monitoring programming is performed after lock is installed on the door For Remote Release wire a normally open contact to wires white and white and momentarily close to allow PL6600 ETPLNRX lock to unlock When Door Monitoring is desired connect these two white wires to the supplied Door Con tact...

Page 9: ...o a new door The lock must be dismantled and powered down for an extended period 1 Disconnect battery pack connector 2 With battery power disconnected short the two white wires Remote Input wires together for 10 seconds to ensure discharge of all capacitors 3 Without touching or turning the handle re connect the battery pack lock will sound 3 short beeps If these 3 beeps are not heard then restart...

Page 10: ...the PL6600 ETPLNRX one time only then their proximity card is dis abled Disable Sounder Disable the Sounder to allow for silent operation Daylight Savings The lock will adjust for Daylight Saving Time See the DL Windows User s Guide OI237 for details Enable Door Monitoring If this feature is checked and the Door Contacts remain open past the time set in Door Ajar Trip Time In Seconds a Door Ajar e...

Page 11: ...ETPLNRX has been programmed for Scheduled Relay Activation Group 1 Initiated and a member of Group 1 has presented their proximity card within the required window Locked by Schedule Activates relay if the PL6600 ETPLNRX has been locked by a programmed schedule Unlocked by Schedule Activates relay if the PL6600 ETPLNRX has been unlocked by a programmed schedule Any Key Press or Card Entry Activates...

Page 12: ... the door without the need for a valid proximity card to be pre sented Remote Disables Lock Regardless of the current state of the lock that state will remain unchanged and the lock will be disabled while the Remote Input wires are shorted Important The Remote Input wires may remain shorted indefinitely therefore if this feature is enabled power to the lock MUST be provided from an external power ...

Page 13: ...13 User Card Record Sheet NAME OF DOOR DEPARTMENT EMBOSSED NUMBER ON CARD USER NAME LAST FIRST DATE ACTIVATED COMMENTS Page ______ ...

Page 14: ...y and the zone input must be pro grammed for input disarming Programmed only through DL Windows GROUP 1 ENABLES GROUP 4 USERS A proximity card previously assigned to Group 1 presented to the lock during a predefined schedule allows access to Group 4 Users Programmed only through DL Windows GROUP 1 PUTS UNIT IN PASSAGE A proximity card previously assigned to Group 1 presented to the lock during a p...

Page 15: ...15 NOTES ...

Page 16: ...or au thorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall ALARM LOCK be liable for an amount in excess of ALARM LOCK s original selling price of the prod uct for any loss or damage whether direct indirect incidental consequential or otherwise arising out of any failure of the pro...