background image

Erase All Programming 

Restore the "out of box" factory condition. 

1.     At the back of the lock, remove the screw at the bottom of the lock housing and remove the cover.   
2.     Disconnect the battery pack connector. 
3.    With battery power disconnected, short the two white wires (

Remote Input 

wires) together for 10 seconds to 

ensure discharge of all capacitors.  After 10 seconds, remove the short.   

4.    Re-connect the battery pack.  The lock will immediately sound 3 short beeps (if these 3 beeps are not heard, 

then restart at step 3).  Within 3 seconds, hold down the outside handle. 

5.    The lock will then sound more slow beeps, 1 beep for every second it takes to clear the memory.  Release the 

handle. 

6.    Lock is ready for programming after 2 rapid beeps are heard and 2 green LED flashes are seen. 

Verifying Proximity Card and Keyfob Access

 

Test by simply presenting a valid proximity card or fob to the reader in front of the lock. 

VALID CARD - 

Green LED flashes, the sounder beeps several times and the PL6600/ETPLNRX unlocks.   

INVALID CARD -

 Red LED flashes several times and the sounder beeps several times.   

Testing the Cards Entered 

Use when re-applying power to a lock already in use (you wish to retain the Lock Program), such as when moving 
an existing lock to a new door.  The lock must be dismantled and powered down for an extended period. 
 

1. Disconnect battery pack connector. 
2. With battery power disconnected, short the two white wires (

Remote Input 

wires) together for 10 seconds to 

ensure discharge of all capacitors. 

3.

Without touching or turning the handle

, re-connect the battery pack (lock will sound 3 short beeps).  If 

these 3 beeps are not heard, then restart at step 1.  The lock will perform several self tests; when complete, 7 
beeps and LED flashes will sound.  The lock is now ready for use. 

Power Up--Retain Existing Programming 

ACTIVITY 

LED 

SOUNDER 

COMMENTS 

Access Granted or  

Remote Release 

2 green flashes 

2 Beeps 

 

Invalid Card / Fob 

7 red flashes 

7 Beeps 

An invalid proximity card / fob does not exist in the Lock 
Program memory. 

Valid but Disabled  

Card / Fob 

1 green, 4 red flashes 

1 Long, 5 Short Beeps 

A proximity card / fob exists in the firmware, but is disabled. 

Emergency Commands 

are in effect  

1 red flash every two 

seconds 

-- 

-- 

Low Battery 

See page 8 ("Battery Replacement) before changing  

batteries.  ("Pass Time" is the duration the lock remains 

unlocked after access is granted). 

Red LED and Sounder turn on steady for the  

duration of the "Pass Time". 

Door Ajar  

1 red flash once every 

second (continues for xx 

seconds) 

-- 

-- 

Forced Door Detection 

(door "kick-in")  

-- 

Steady tone  

for xx seconds 

-- 

LED and Sounder Indicators 

With a fully charged battery, the LED and sounder provide visual and audible feedback as follows: 

Summary of Contents for Networx ETPLNRX

Page 1: ...ARD READER ENROLLER PROXKEY KEYFOB HID HID HID CORPORATION PROXCARD DL WINDOWS PROGRAMMING SOFTWARE PL6600 ETPLNRX 345 Bayview Avenue Amityville New York 11701 For Sales and Repairs 1 800 ALA LOCK For Technical Service 1 800 645 9440 or visit us at http tech napcosecurity com Note Technical Service is for security professionals only Publicly traded on NASDAQ Symbol NSSC ALARM LOCK 2013 ...

Page 2: ...Audit Log Data may be transmitted through the radio link back to the DL Windows computer To increase security PL Series locks do not include keypads instead these models feature an HID compatible ProxCard reader In addition data can be retrieved from the lock to your PC with DL Windows software Its real time clock calendar automatically adjusts for Daylight Saving Time and allows for automated pro...

Page 3: ...e 11 Scheduling Using DL Windows 500 Scheduled Events see page 11 Automated Unlock Lock see pages 10 and 11 Enable Disable Users see page 6 for definition of User Enable Disable Groups see page 7 for definition of Group Real time clock and calendar User Access Methods ProxCard and ProxKey Keyfob Note ProxCards and ProxKey Keyfobs function identically User Features 5000 Users Service Card One Time ...

Page 4: ...LAN or corporate Intranet A Windows PC connected to this network can control and program all PL6600 ETPLNRX locks by the use of the DL Window software see OI237 and OI352 With access rights to the software one computer or several can control the software and consequently can control the devices in the system Several Gateway device models are available Wireless Wired AL IM80211 Hardwired Wireless G...

Page 5: ... in hand One additional advantage is that proximity cards and fobs cannot be dupli cated unlike ordinary metal keys Preparing to Program your Lock As the PL6600 ETPLNRX does not feature keypad buttons on its housing programming your PL6600 ETPLNRX for example adding or deleting proximity cards is allowed only using a PC that is running the computer software ap plication DL Windows The PC must be c...

Page 6: ...to suit the needs of your various installations For exam ple you can program the lock to allow Group 1 Users access ONLY during specific business hours unlock at 9AM lock at noon for lunch unlock at 1PM and lock again at 5PM every weekday In addition DL Windows makes Schedule creation much easier In DL Windows use the Schedule TimeZone screen to first create an individual block of time called a Ti...

Page 7: ...roximity card assigned to User Number 297 pos sesses the unique ability to enable the proximity card assigned to User Number 300 When proximity card 297 is presented to the lock proximity card 300 is en abled for one time use allowing passage for one time only Once used User 300 s proximity card becomes disabled For example you wish to allow one time access to a temporary worker Simply present pro...

Page 8: ...White White wires These two white Remote Input wires can be programmed as a Remote Release or for Door Monitoring programming is performed after lock is installed on the door For Remote Release wire a normally open contact to wires white and white and momentarily close to allow PL6600 ETPLNRX lock to unlock When Door Monitoring is desired connect these two white wires to the supplied Door Con tact...

Page 9: ...o a new door The lock must be dismantled and powered down for an extended period 1 Disconnect battery pack connector 2 With battery power disconnected short the two white wires Remote Input wires together for 10 seconds to ensure discharge of all capacitors 3 Without touching or turning the handle re connect the battery pack lock will sound 3 short beeps If these 3 beeps are not heard then restart...

Page 10: ...the PL6600 ETPLNRX one time only then their proximity card is dis abled Disable Sounder Disable the Sounder to allow for silent operation Daylight Savings The lock will adjust for Daylight Saving Time See the DL Windows User s Guide OI237 for details Enable Door Monitoring If this feature is checked and the Door Contacts remain open past the time set in Door Ajar Trip Time In Seconds a Door Ajar e...

Page 11: ...ETPLNRX has been programmed for Scheduled Relay Activation Group 1 Initiated and a member of Group 1 has presented their proximity card within the required window Locked by Schedule Activates relay if the PL6600 ETPLNRX has been locked by a programmed schedule Unlocked by Schedule Activates relay if the PL6600 ETPLNRX has been unlocked by a programmed schedule Any Key Press or Card Entry Activates...

Page 12: ... the door without the need for a valid proximity card to be pre sented Remote Disables Lock Regardless of the current state of the lock that state will remain unchanged and the lock will be disabled while the Remote Input wires are shorted Important The Remote Input wires may remain shorted indefinitely therefore if this feature is enabled power to the lock MUST be provided from an external power ...

Page 13: ...13 User Card Record Sheet NAME OF DOOR DEPARTMENT EMBOSSED NUMBER ON CARD USER NAME LAST FIRST DATE ACTIVATED COMMENTS Page ______ ...

Page 14: ...y and the zone input must be pro grammed for input disarming Programmed only through DL Windows GROUP 1 ENABLES GROUP 4 USERS A proximity card previously assigned to Group 1 presented to the lock during a predefined schedule allows access to Group 4 Users Programmed only through DL Windows GROUP 1 PUTS UNIT IN PASSAGE A proximity card previously assigned to Group 1 presented to the lock during a p...

Page 15: ...15 NOTES ...

Page 16: ...or au thorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall ALARM LOCK be liable for an amount in excess of ALARM LOCK s original selling price of the prod uct for any loss or damage whether direct indirect incidental consequential or otherwise arising out of any failure of the pro...

Reviews: