12
Quick Start (cont’d)
Delete a User Code
1. Enter Program Mode (if not in already).
2. Press
;
2
;
[
User Number
]
:
.
The sounder beeps for 10 seconds with green (and then red) LED flashes. At this point the lock expects a presentation of a
proximity card; but do nothing -- simply wait for the beeping to time-out (10 seconds). When beeping stops, the proximity and
User Code data will be erased.
3. Repeat step 2 for each new User.
User Code Conflicts
Care should be taken not to program a new User Code which matches the first digits of any other User Code (only the User
Code with the least number of digits will be recognized).
Example:
If User Codes 123 and 123456 are both entered in the
system, only code 123 would be recognized, unless the ENTER Key has been enabled (see Function 69, see page 24). In ad-
dition, an error will sound if you try to program a new User Code that matches the first digits of the Master Code.
WARNING: When attempting to change an existing Master Code, it is HIGHLY recommended that you enable all
Groups (see Function 23 on page 17), exit Program Mode, and enter the new anticipated Master Code to verify that the
anticipated sequence does not currently open the lock. If the lock does not open, the anticipated Master Code can be
used as the new Master Code; if the lock opens, the anticipated Master Code already exists in the lock (as a User
Code), and the anticipated Mater Code should NOT be used. Always repeat this procedure with any new anticipated
Master Codes.
Enroll Proximity Cards at the Lock
If you wish to enroll only one proximity card ("Single Enrolling") or many ("Batch Enrolling"), the process is basically the
same.
1. Enter Program Mode (if not in already).
2. Press
;
2
;
[
User Number
]
:
. (Enter the User Number you wish to match with the first proximity card).
3. Lock will beep continuously. Place a new proximity card in front of the reader (under the lock keypad). When the
lock beeps three times, the card has been enrolled.
4. Press
;
to end the process. To return to normal operation, exit Program Mode (see below).
(For example, you wish to enroll two proximity cards for User 14 and User 15 respectively. Press
;
2
;
1
4
:
. and place the first card in front of the reader (hear 3 beeps) and then within 10 seconds, place the
second card in front of the reader (hear 3 beeps)).
You can continue entering cards in this way, automatically incrementing the User number with each presentation of a
proximity card. When finished, press
;
.
Note:
Batch Enrolling will not program Users 297 through 300, as these are
Special Function
User Codes. After a
proximity card for User 296 has been Batch Enrolled, the next card presented will enroll as User 301.
High Security Access (ProxCard & User Code Access)
Program the lock for High Security Access for
User Number 15
, with a
proximity card
and
a
User Code of 7452
required for
access:
1. Enter Program Mode (if not in already).
2. Press
;
2
;
1
5
:
.
3. Lock will beep continuously. Place a new
proximity card
in front of the reader (under the lock keypad). When the lock
beeps three times, the card has been enrolled.
4. Press
;
2
;
1
5
;
7
4
5
2
:
.
In order for User 15 to open the Lock, a User Code must be entered and a
proximity card
must be presented to the
PDL6100 Lock. User may enter code or present card
in either order
to open the lock. The sounder will beep for up to 10
seconds, waiting for the User to enter their User Code and present their card.
Delete a High Security Access Code
Note:
Deleting a
proximity card
associated with a User Number will also delete the User Code programmed for that User
Number. Delete the
proximity card
by not presenting any card for enrollment, as follows:
1. Enter Program Mode (if not in already).
2. Press
;
2
;
_
:
. (Enter the User Number matched to the
proximity card
you want to delete).