23

 

 

;

 

6

 

7

    

;

 

[ _ _ ]

 

:

 

       (Event Number) 

67. Add System Features

 

SYSTEM FEATURES

 

68. Delete All Relay Features added by Function 67.  

 

;

 

6

 

8

   

;

 

0

 

0

 

0

 

:

 

Relay Features 

(12-23. Reserved) 

 

Use Function 67 to program 

one or more 

lock events and the Relay will energize when the programmed event(s) listed below oc-

curs.  For example, program 

;

 

6

 

7

 

;

 

3

 

:

 and when an attempted entry fails (such as a User who enters an 

incorrect or un-programmed User Code), the Relay will energize for 2 seconds.  

Note:

  For more information about the 

Remote In-

put

, see page 10 (Wiring, Remote Input) and page 22 (Function 65).

 

1.    

Remote Input switch closed and Function 65 

Remote Input 

enabled.  

Because the Remote Input is enabled by factory default, the Relay will 
energize when the Remote Input switch is closed. 

9.     

Lock Out.  

Relay energizes for 2 seconds when a Lock Out occurs (i.e. 

number of attempts is exceeded, see Function 60). 

2.    

Remote Input switch closed and Function 64 

Remote Input 

dis-

abled.  

If the Remote Input is disabled with Function 64, the Relay will 

energize when the Remote Input Switch is closed. 

10.    

Ambush.  

Relay energizes for 2 seconds when Ambush is tripped.  See 

Function 66, page 22. 

3.    

Failed attempted entry.

  Relay energizes for 2 seconds when an at-

tempted User Code entry (or proximity card / keyfob) fails. 

11.    

First Key Press.  

Relay energizes for 2 seconds at the first key press of 

any sequence. 

4.    

Disabled User or Group.  

Relay energizes for 2 seconds when a dis-

abled User or disabled Group member enters a User Code (or proximity 
card / keyfob). 

5.    

Follow Access Granted. 

 When a valid User Code is entered into the 

keypad and the lock unlocks, the Relay energizes for 2 seconds.  Com-
pare with Event 31. 

6.    

Group 1 User Code.  

Relay energizes for 2 seconds when a scheduled 

Group 1 User Code (or proximity card / keyfob) is entered.  See 
Function 90, page 26. 

7.    

Scheduled Lock Event.

  Relay energizes for 2 seconds when lock is 

locked by a Schedule. 

8.    

Scheduled Unlock Event.  

Relay energizes for 2 seconds when lock is 

unlocked by a schedule 

31.    

Follow Access Granted--No Time Limit.**  

When a valid User Code is 

entered into the keypad and the lock unlocks, the Relay energizes for 
the 

same amount of time as the programmed Pass Time

.  (The Pass 

Time is the length of time the lock stays unlocked after a valid 
User Code is entered.  See functions 52-54).  Use this feature for 
remote monitoring or other activation as this feature works independ-
ently of all other relay options.  Programming this feature will supersede 
all other programmed relay features.  Subsequent relay feature pro-
gramming will not take effect while this feature is active.  Before pro-
gramming any other relay features, press 

;

 

6

 

8

 

;

 

0

 

0

 

0

 

:

 to delete this feature. 

 

4

 

System Options 

 

24.   One Time Access for Group 3 Users*** 
25.     Disable  Sounder 
26.   5 sec. Delayed Entry * 
27.   15 sec. Delayed Entry * 
28.   45 sec. Delayed Entry * 

Remote Input Functions

 

29.  

Toggle Passage Mode.  

Remote Input toggles Passage Mode.   

30.  

Forced Unlock Follows Remote Input.

**  When Remote Input switch 

is closed, regardless of the current state of the lock, the lock unlocks for 
the duration of the Remote Input switch closure. 

32.  

Remote Input Disables Unit.

** 

 

Regardless of the current state, that 

state will remain unchanged (and keypad will be disabled) for the dura-
tion of Remote Input switch closure. 

34.  

Forced Lock Follows Remote Input 

**  When Remote Input switch is 

closed, regardless of the current state of the lock, the lock will lock for 
the duration of the Remote Input switch closure. 

*  Features 26, 27 & 28 will delay User Codes 12 and higher only (except 297, 298 and 299, and any Emergency Command enabled User). 
** Features 30, 31 & 32 should be used with External DC Power unless feature is used for short a duration and infrequently (sustained closure of remote input or Relay 

will drain batteries, and scheduled events will not occur during sustained closure of remote input).  Sustained closure of remote input may affect proper audit trail 
operation.  

NOTE:  

Enter 

;

 

6

 

7

 

;

 

0

 

0

 

0

 

:

 to delete all Relay Features added by Function 67 (identical to Function 68). 

*** Feature 24, "One Time Access for Group 3 Users", allows the creation of multiple 'one time only' User Codes.  When activated, an entry by a Group 3 User allows entry 

only once, then user becomes disabled.  

Note:

  When the User Code is entered for the first time and access is granted, the Event Log will read "Entry" followed by 

"User Disabled".  If the User Code is entered a second time, access will be denied, and the Event Log will read "User Denied Access".  

 

To Enable the Feature:

  Enter Program Mode and enter the key sequence 

;

 

6

 

7

 

;

 

2

 

4

 

:

.  

To assign the selected User Codes to 

Group 3:   

For example, to assign User Number 15 to Group 3, press:  

;

 

3

 

5

 

;

 

1

 

5

 

;

 

3

 

:

 Emergency Commands are disabled until a download from DL-Windows is performed.  If a Function 67 or 68 (Clear Relay) is performed, Emergency Commands 

are turned off. 

Enter 

;

 

6

 

8

   

;

 

0

 

0

 

0

 

:

 to delete all Relay Features added by Function 67.   

 

4

 

Programming Functions (cont'd) 

Ambush Function 

1.  

Connect relay to a device able to properly monitor dry contacts for an 

Ambush 

condition. 

2.  

Program the Relay for 

Ambush Tripped

 using Program Function 67(10) above. 

3.  

Set the Ambush Code using Program Function 66.  

4.  

When the Ambush Code is entered followed by a valid User Code, the relay will close for 2 seconds. 

Notes:  

The Ambush Code defaults to 

99

.  An error will sound if you try to program a new User Code starting with the Ambush Code. 

Enable Emergency Commands

 

38.   Emergency Commands Enable (default = ON) 
39.   User Lockout on Emergency (default = ON) 

Summary of Contents for PDL6100

Page 1: ...ales and Repairs 1 800 ALA LOCK For Technical Service 1 800 645 9440 Publicly traded on NASDAQ Symbol NSSC ALARM LOCK 2012 HID HID CORPORATION PROXIMITY CARD AL PRE PROXIMITY CARD READER ENROLLER DL WINDOWS PROGRAMMING SOFTWARE PDL6100 PROXIMITY KEYFOB AL IM SERIES GATEWAY MODULE AL IM80211 AL IME AL IMEPOE ...

Page 2: ...es an HID compatible ProxCard reader and a real time clock calendar that automatically adjusts for Daylight Saving Time and allows for auto mated programming of events Up to 5000 unique user codes can be added to the lock from 3 6 digits in length Wireless Network and DL Windows If your Networx wireless network is not yet set up you can add Users and program other features using the PDL6100 keypad...

Page 3: ... For highest security see page 12 Batch Enroll Quickly and easily enroll multiple ProxCards and ProxKey keyfobs without the use of a PC see page 12 Note ProxCards and ProxKey Keyfobs both function identically Keyfobs can be sub stituted for all references to the ProxCard in this manual User Features 5000 Users see pages 11 12 15 5 Pre defined Administration User Levels including Master Installer M...

Page 4: ... PC connected to this network can control and program all PDL6100 locks by the use of the DL Window software see OI237 and OI352 With access rights to the software one computer or several can control the software and consequently can control the devices in the system Several Gateway device models are available Wireless Wired AL IM80211 Hardwired Wireless Gateway Interface Module Supplied with its ...

Page 5: ...am Mode When you want to make changes to the lock program you enter Program Mode When you finish programming and wish to put the lock into use you exit Program Mode to enter Normal Mode You can enter Program Mode using the keypad by pressing the Master Code of the lock that was set at the factory then wait for the green light and press until multiple beeps are heard The Master Code is basically a ...

Page 6: ...tasks a User is allowed to perform The higher the Level the more pro gramming tasks the User is allowed with Master allowing ALL tasks Note Since the Programming Level is closely associated with the type of User and their abilities a User who holds a certain Program ming Level is sometimes referred to by their User Type For example PDL Series locks can hold up to 5000 Users in its pro gramming mem...

Page 7: ...to issue Global Lock Down to lock all doors in the Account press 000 to issue Global Passage to unlock all doors in the Account press 123 to return all locks in the Account to normal non emergency operation Note 3 chirps sound after each emergency command entry See the DL Windows user guide OI352 Emergency Lock Down for more information Note DL Windows does not need to be run ning to allow these E...

Page 8: ...mming Level as follows Master Always associated with User number 1 Is always enabled and can program all functions Abbreviated as Programming Level M Installer Always associated with Users 2 and 3 Can pro gram all functions except changing the Master Code Abbreviated as Programming Level 4 Manager Always associated with Users 4 5 and 6 Can program all functions except functions relating to lock co...

Page 9: ...ler 3 Manager 2 Supervisor This Program Level abbreviation is the minimum program level required to access the particular Function The higher the level the more programming tasks the User is allowed with Master allowing all tasks Function Description Function Number Function Name ACTIVITY LED SOUNDER COMMENTS Keypress 1 Red Flash 1 Beep Normal Operation Access Granted or Remote Release 2 Green Fla...

Page 10: ... the battery pack lock will sound 3 short beeps If beeps are not heard then restart at step 1 4 Within 5 seconds after hearing the 3 short beeps press and hold until the lock begins to beep then release 5 A series of 5 RED LED and 5 beeps will be heard followed by 10 seconds of silence then 3 GREEN LEDs and 3 fast beeps All settings and programming have been erased and the lock is now ready for us...

Page 11: ...Code to be 664433 Press 1 664433 664433 Now that the Master Code has been changed there is no need to change it again unless you want to Since you are still in Program Mode you can now proceed directly below and program various functions Note Programming any Function such as setting the clock follows a consistent 5 step pattern 1 Enter Program Mode 2 Press Function 3 Press and enter data 4 Press t...

Page 12: ...y card 3 Lock will beep continuously Place a new proximity card in front of the reader under the lock keypad When the lock beeps three times the card has been enrolled 4 Press to end the process To return to normal operation exit Program Mode see below For example you wish to enroll two proximity cards for User 14 and User 15 respectively Press 2 1 4 and place the first card in front of the reader...

Page 13: ...urity Access The proximity card or keyfob and a User Code are both required for access 1 Enter the User Code for the User Number programmed for High Security Access The sounder will beep slowly for up to 10 seconds 2 Present the proximity card programmed for the same User Number User may enter User Code or present the proximity card in either order to open the lock The sounder will beep for up to ...

Page 14: ...ge 20 Function 47 Timed Passage Mode See page 20 Programming Functions Overview Function 48 Enable Passage Mode See page 21 Function 49 Disable Passage Mode See page 21 Function 50 Return Lock to Normal Passage Mode Schedule See page 21 Function 51 Passage Mode Configuration See page 21 Function 52 54 Pass Time See page 21 Function 55 Reserved Function 56 Reserved Function 57 Reserved Function 58 ...

Page 15: ...oor 1 New Master Code User Number 1 1 _ _ _ _ _ _ _ _ _ _ _ _ New Master Code Confirm New Master Code 2 Adding and Deleting User Codes and or Proximity Cards for User Numbers 2 5000 2 _ _ _ _ _ _ _ _ _ _ User Number User Code Master Code must be 6 digits only Master Code is Keypad Code Access only Factory Default 123456 See Lock Design Overview on page 5 for more information about Master Codes M U...

Page 16: ...ork day by entering Program Mode and pressing 5 1157 008 NOTE Up to 4 Timeout Functions may be pending at any one time An error beep will sound when attempting to program more than 4 Timeout Functions 2 Service Code is a One Time Only Code Once it is used it is disabled until enabled again NOTE User Number 297 is used to reset Service Code Use See Terminology Used in this Manual on page 7 for more...

Page 17: ...remain 3 13 Clear All Timeout Functions This Function enabled through keypad only CLEAR FUNCTIONS Group Enable Disable Enter the functions below to Enable Disable Groups Functions 14 23 will each override existing scheduled events Therefore Functions 14 23 are temporary take effect im mediately and are always overridden by future scheduled events that already exist within the lock programming 2 GR...

Page 18: ... Association As per the chart on page 8 the lock s default programming from the factory associates certain User Numbers with certain Groups To override these default Group associations Function 35 manually associates or disassociates a selected User with a selected Group During programming Groups not selected are then disassociated from the User Function 35 is helpful when the number of Users you ...

Page 19: ...nd ends at 2AM on the programmed date Enter 4 1 0 0 0 to disable DST All locks leave the factory with DST enabled and pre programmed to the following start and end dates for the USA beginning 2007 Default DST Start Date March Week 2 Sunday Second Sunday in March Default DST End Date November Week 1 Sunday First Sunday in November To program the DST start date using the keypad press 4 1 M M W D whe...

Page 20: ...s Note Repeated use of these Functions are not cumulative this means for exam ple if the clock has already been set to speed up 10 seconds per day and then is found to need an additional 10 seconds then program 20 seconds using Function 43 Example 1 Clock is losing 13 seconds every day enter 4 3 1 3 This example assumes that the Clock Adjust setting was at the factory default of zero Example 2 Clo...

Page 21: ...Code is entered When the Pass Time expires the lock will re lock automatically Use the functions below to change the Pass Time to 3 10 or 15 seconds The Pass Time is defaulted to 3 seconds Pass Time 4 53 Set Pass Time to 10 Sec 54 Set Pass Time to 15 Sec PASS TIME See Scheduled functions 72 and 73 for Scheduled Passage Mode NOTE 51 Passage Mode Configuration 5 1 _ Mode Mode 1 Normal Passage Mode m...

Page 22: ...UT 6 4 64 Disable Remote Input Wire a Normally Open Contact to Wires White White Momentarily close switch to unlock door to allow person to pass through door Enter the functions below to Disable Enable the Remote Input NOTE The Remote Input is enabled as part of the default program Remote Input 6 5 65 Enable Remote Input 6 6 _ _ Ambush Code 66 Ambush Code Ambush code must be 2 digits An error will...

Page 23: ... 6 8 0 0 0 to delete this feature 4 System Options 24 One Time Access for Group 3 Users 25 Disable Sounder 26 5 sec Delayed Entry 27 15 sec Delayed Entry 28 45 sec Delayed Entry Remote Input Functions 29 Toggle Passage Mode Remote Input toggles Passage Mode 30 Forced Unlock Follows Remote Input When Remote Input switch is closed regardless of the current state of the lock the lock unlocks for the ...

Page 24: ...2 8 0 _ _ _ _ _ Day Time 81 Schedule Disable Group 3 8 1 _ _ _ _ _ Day Time 82 Schedule Disable Group 4 8 2 _ _ _ _ _ Day Time 83 Schedule Disable All Groups 8 3 _ _ _ _ _ Day Time 3 Clear All Schedule and Timeout Functions by entering Function 12 To set the time see Function 39 NOTE 72 Schedule Enable Passage Mode Unlock 7 2 _ _ _ _ _ Day Time 73 Schedule Disable Passage Mode Lock 7 3 _ _ _ _ _ D...

Page 25: ...7 for Saturday 8 for Monday to Friday 9 for Saturday and Sunday and 0 for all days of week Enter time of day in 24 hour format for example for 2 15 PM enter 14 15 Scheduled Passage Mode Group 1 Activated 89 Passage Mode Close Time Window This Function enabled through keypad only 8 9 _ _ _ _ _ Day Time SCHEDULES GROUP 1 ACTIVATED 3 For your convenience your lock comes pre programmed with Quick Sche...

Page 26: ...me of day in 24 hour format for example for 2 15 PM enter 14 15 Scheduled Relay Activation Group 1 Activated 9 1 _ _ _ _ _ Day Time 91 Relay Activation Close Time Window SCHEDULES GROUP 1 ACTIVATED 3 NOTES 1 Group 1 Disarms a Burglary Control Panel will always disarm an alarm system Arming should be performed by other means such as Alarm Panel Keypad Schedule 2 Use a qualified electrical alarm spe...

Page 27: ...or Monday to Friday 9 for Saturday and Sunday and 0 for all days of week Enter time of day in 24 hour format for example for 2 15 PM enter 14 15 3 Programming Functions cont d 93 Enable Group 4 Close Time Window This Function enabled through keypad only 9 3 _ _ _ _ _ Day Time Scheduled Group 4 Enable Group 1 Activated Disable Radio Signal 94 Disable Radio This Function enabled through keypad only ...

Page 28: ...tion See To Disarm a Burglary Control Panel on page 26 If a Group 1 User does not enter their User Code during the specified window Func tions 90 91 remain inactive Function 92 and 93 allow for a window of time to be created where if any Group 1 User Code is entered within the programmed window the User Codes in Group 4 will be enabled If a Group 1 User does not enter their User Code during the sp...

Page 29: ...n of the alarm panel Functions 92 93 Use Function 92 and 93 see page 27 to create a window of time where if any Group 1 User Code is entered within the programmed window Group 4 Users will be enabled 1 Enter Program Mode if not in already 2 Using Function 2 create User 4 with a User Code of 456789 Press 2 4 4 5 6 7 8 9 3 Because User 4 does not have a default Group association make User 4 a member...

Page 30: ...e Input enabled 2 Remote Input switch closed and Function 64 Remote Input disabled 3 Failed attempted entry 4 Disabled User or Group 5 Follow Access Granted 6 Group 1 User Code 7 Scheduled Lock Event 8 Scheduled Unlock Event 9 Lock Out 10 Ambush 11 First Key Press 25 Disable Sounder 26 5 sec Delayed Entry 27 15 sec Delayed Entry 28 45 sec Delayed Entry 29 Toggle Passage Mode 30 Forced Unlock Follo...

Page 31: ...31 User Number 1 5000 User Code 3 6 digits User Name 1 2 3 4 Group Association For a complete list of user codes obtain a printout from the DL WINDOWS software Note ...

Page 32: ...32 User Number 1 5000 User Code 3 6 digits User Name 1 2 3 4 Group Association For a complete list of user codes obtain a printout from the DL WINDOWS software Note ...

Page 33: ...unctions can be programmed For Day Enter 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday 8 Monday through Friday 9 Saturday and Sunday 0 All days of the week Enter time of day in 24 hour format 00 00 23 59 Time Function Name ...

Page 34: ...unctions can be programmed For Day Enter 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday 8 Monday through Friday 9 Saturday and Sunday 0 All days of the week Enter time of day in 24 hour format 00 00 23 59 Time Function Name ...

Page 35: ...are permanently encoded within the lock s fixed memory and when the lock is first started or when power is removed and re applied see Wiring and Power Up page 10 the original factory default settings are re loaded and take effect DISABLE Turn off DOWNLOAD Send data to the PDL6100 EMERGENCY COMMANDS For use with the Trilogy Net worx wireless network only Wireless commands can be sent to all wireles...

Page 36: ...l shipping costs prepaid and insured to ALARM LOCK After repair or replacement ALARM LOCK assumes the cost of returning products under warranty ALARM LOCK shall have no obligation under this warranty or otherwise if the product has been repaired by others improperly installed improperly used abused altered damaged subjected to accident nuisance flood fire or acts of God or on which any serial numb...

Reviews: