ADDENDUM
REPOSITION THE
PRECISION 1100 RECEPTACLE
WI1580 10/06
345 Bayview Avenue
Amityville, New York 11701
For Sales and Repairs 1-800-ALA-LOCK
For Technical Service 1-800-645-9440
Publicly traded on NASDAQ Symbol: NSSC
© ALARM LOCK 2006
HOW TO REPOSITION THE RECEPTACLE
For the Precision 1100 model to work correctly with the NAPCO Exit Trim models, the 1100 model receptacle must be
located at the bottom of the unit. If the 1100 model receptacle is located at the top position (either from pre-existing
installations or new installations), the receptacle must be repositioned as shown the image below.
INCORRECT
CORRECT
Receptacle must
be repositioned
Receptacle
repositioned
correctly
Precision 1100
Precision 1100
4. Turn back plate 180° so that the receptacle is
in the bottom position.
6. Receptacle repositioned correctly.
5. Replace all 4 screws that were previously
removed in step 2.
Receptacle
2. Remove all 4 screws with a slotted screw-
driver. Place screws aside.
3. With screws removed, the back plate can easily be
removed as a modular unit.
1. The underside of the model 1100 is shown, with
four (4) screws that must be removed.
Screw 1
Screw 2
Screw 3
Screw 4
Receptacle