OVERVIEW 

 The 

Trilogy 

Networx

 

AL-IME2-EXP  Expander 

extends 

the coverage area of version 2 series Gateways, allowing 
control of up to its rated maximum of 63 Networx locks per 
Gateway.  Installation is simple, as the Expander only re-
quires a connection to an AC outlet. 

 

AL-IME2-EXP

 Expanders are cost-effective, easier to wire 

than conventional Gateways, and feature a simplified 'Plug 
and Play' setup where the Networx system automatically 
identifies all newly powered Expanders and quickly deter-
mines the best wireless signal pathways.  Up to 7 Expanders 
can be added to one version 2 series Gateway.   

 

 

Why use AL-IME2-EXP Expanders?

 



Less costly, Expanders can be used in place of addition-
al Gateways 



Does not require network access / Ethernet cables 



Extends wireless lock signal coverage 



Reach otherwise troublesome locks in areas of insuffi-
cient signal strength 



Allows for easier (flexible) positioning of version 2 Gate-
ways 



Allows large area signal coverage with a single network 
connection to the Gateway 

 

Note: 

 Expanders are available in two different designs, 

the 

AL-IME2-EXP 

and the 

AL-IME2-PIE  Plug-In Expander 

(identical in operation, the compact 

AL-IME2-PIE

 plugs di-

rectly into a standard 120VAC un-switched/uninterruptable 
wall outlet).   

 

 Version 

 

 The 

AL-IME2-EXP 

" version 2"  Expanders (notice the "

2

in the model name) are the next generation of Networx wire-
less devices.  Because 

AL-IME2-EXP

 Expanders 

only 

work with version 2 Gateways, a version 2 Gateway must be 
installed and operational in your system for 

AL-IME2-EXP

 

Expanders to function (

AL-IME2-EXP

 Expanders cannot 

communicate with older "non-version 2" Gateways). 

 

 

Note:

  Although the version 2 Gateways and 

AL-IME2-

EXP

 Expanders CAN be mixed into an existing system 

that includes older "non-version 2" Gateways, 

at least one 

new version 2 Gateway must be up and running before an 
AL-IME2-EXP Expander can be used

.   

 

 

IMPORTANT:

   

DL-Windows version 5.4.2 

or later is re-

quired to support version 2 Gateways and Expanders.  

 

 The 

AL-IME2-EXP

 Expander is compatible with Alarm 

Lock and Continental Access products.  Refer to the docu-
mentation supplied with your software for integration details.   

 

AL-IME2-EXP SPECIFICATIONS 

NETWORK RANGE 

Gateway/Expander to Locks:  Clear field range 500'. 
Typical indoor range: Networx 75-175'; ArchiTech Networx: 
50-125'.  

Note: 

 Actual range varies with building con-

struction.   

AL-IME2-EXP Expander 

Installation Instructions 

© ALARM LOCK 2018 

WI2156BLF  1/18 

Gateway/Expander to Expander:  Clear field range 500'.  
Typical indoor range, 75- 175'.  

Note:

  Actual range varies 

with building construction. 

 

AL RADIO LINK 

900 MHz GFSK 
50 Channels 
10mW power output 

 

POWER

 - Provided by UL Listed Class 2 Transformer

 

Peak Supply Current:  150mA 
Input Voltage:  5 - 6VAC 
Includes one (1) 6VAC External Power Supply 

 

ENVIRONMENTAL 

Operating Temperature:  -20

˚

 to 60

˚

C (-4

˚

 to 140

˚

F) 

Storage Temperature:  -40

˚

 to 85

˚

C (-40

˚

 to 185

˚

F) 

 

PHYSICAL 

Enclosure Size:  4.5"H x 6.0"W x 1.94"D 
Weight:  0.5lbs. 

 

EXPANDER LOCATION GUIDELINES 

  Once your version 2 Gateway location has been selected, 

the next step is to determine where to mount the Expander.  
However, the following must be taken into consideration: 

 



Generally, the Expanders should be within approximately 
75 feet (radially) from the Gateway or another Expander  



Expanders should be located within 100 feet (radially) from 
the intended wireless lock locations 



Open areas will increase range while concrete building 
construction, walls, ceilings and narrow corridors will 
decrease range 



ArchiTech series locks generally have shorter range to/
from an Expander  



Select a location that allows access to the power wires 
running from the 6VAC power transformer (supplied)   



Expanders should be mounted in elevated areas; however 
mounting in a drop ceiling can adversely affect signal 
strength 



Preferred mounting position = 6 to 12" below ceiling 



Expanders must be mounted vertically; horizontal "flat" 
mounting of the Expander should be specifically avoided 



Although wood and wallboard construction can have little 
effect upon signal strength, concrete or brick can reduce 
signal strength by up to 35%.  Steel-reinforced concrete or 
metal lath and plaster can reduce signal strength as much 
as 90%! 



Do NOT mount close to electrical wiring or other metal 
obstructions such as pipes or conduits   



Installing in computer closets or server rooms can nega-
tively impact signal strength 

 

 Helpful 

Tips 



The 

AL-NSM 

Networx Signal Meter and the 

AL-NSG 

Networx Signal Generator can assist with identifying 

345 Bayview Avenue 

Amityville, New York 11701 

For Sales and Repairs 1-800-ALA-LOCK 

For Technical Service 1-800-645-9440  

or visit us at 

http://tech.napcosecurity.com/ 

(Note:  Technical Service is for security professionals only)

 

Publicly traded on NASDAQ    Symbol: NSSC

 

Summary of Contents for Trilogy Networx AL-IME2-EXP

Page 1: ...ge Networx 75 175 ArchiTech Networx 50 125 Note Actual range varies with building con struction AL IME2 EXP Expander Installation Instructions ALARM LOCK 2018 WI2156BLF 1 18 Gateway Expander to Expander Clear field range 500 Typical indoor range 75 175 Note Actual range varies with building construction AL RADIO LINK 900 MHz GFSK 50 Channels 10mW power output POWER Provided by UL Listed Class 2 Tr...

Page 2: ...pander installation location We recommend obtaining or creating a layout of your intended system identifying all proposed installation lo cations also noting building construction materials IMPORTANT Be sure to read the EXPANDER GROUP DIALS section on page 3 before powering your Expanders The above guidelines and tips should be followed for each additional Expander added to the system See next sec...

Page 3: ...l setting Note Zero No blink Yellow LED solid green LED flickering rapidly Next reset the Expander as follows Reset the Expander IMPORTANT Before securing the Expander housing cover ALWAYS reset the Expander memory even if the Expander is new out of the box and or has never been used previously After initial power up press and hold the RESET button see below for location continue to hold the butto...

Page 4: ...anty contains the entire warranty It is the sole warranty and any prior agreements or representa tions whether oral or written are either merged herein or are expressly cancelled ALARM LOCK neither assumes nor authorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall ALARM LOCK be li...

Reviews: