background image

18

 

Function 1 

Change Master Code 

See page 19 

Function 2 

Add/Delete/Change User Codes 

See page 19 

Function 3 

User Disable (By User Number) 

See page 20 

Function 4 

User Enable (By User Number) 

See page 20 

Function 5 

User Enable with Timeout 

See page 20 

Function 6 

Enable Total User Lockout 

See page 20 

Function 7 

Disable Total User Lockout 

See page 20 

Function 8 

Reserved 

-- 

Function 9 

Enable User 300 (Service Code) 

See page 20 

Function 10 

Erase All Users Except the 
Master Code 

See page 20 

Function 11 

Reserved 

-- 

Function 12 

Clear All Schedules and Timeout 
Functions 

See page 21 

Function 13 

Clear All Timeout Functions 

See page 21 

Function 14 - 17 

Group 1-4 Disable 

See page 21 

Function 18 

Disable All Groups 

See page 21 

Function 19 - 22 

Group 1-4 Enable 

See page 21 

Function 23 

Enable All Groups 

See page 21 

Function 24 

Reserved 

-- 

Function 25 - 28 

Group Disable with Timeout 

See page 22 

Function 29 

Disable All Groups with Timeout 

See page 22 

Function 30 - 33 

Group Enable with Timeout 

See page 22 

Function 34 

Disable All Groups with Timeout 

See page 22 

Function 35 

Group Add/Delete Association 

See page 22 

Function 36 - 37 

Reserved 

-- 

Function 38 

Set Date 

See page 23 

Function 39 

Set Time 

See page 23 

Function 40 

Set Weekday 

See page 23 

Function 41 

Daylight Saving Time Start Date 

See page 23 

Function 42 

Daylight Saving Time End Date 

See page 23 

Function 43 

Speed Up Clock 

See page 24 

Function 44 

Slow Down Clock 

See page 24 

Function 45 - 46 

Passage Mode Enable/Disable 

See page 24 

Function 47 

Timed Passage Mode 

See page 24 

Programming Functions--Overview 

Function 48 

Enable Passage Mode 

See page 25 

Function 49 

Disable Passage Mode 

See page 25 

Function 50 

Return Lock to Normal Passage 
Mode Schedule 

See page 25 

Function 51 

Passage Mode Configuration 

See page 25 

Function 52 - 54 

Pass Time 

See page 25 

Function 55 

Reserved 

-- 

Function 56 

Reserved 

-- 

Function 57 

Reserved 

-- 

Function 58 

Reserved 

-- 

Function 59 

Reserved 

-- 

Function 60 

Number of Attempt Before 
Lockout 

See page 26 

Function 61 

Set the Attempts Lockout Time 

See page 26 

Function 62 - 63 

Reserved 

-- 

Function 64 - 65 

Disable/Enable Remote Input 

See page 26 

Function 66 

Ambush Code 

See page 26 

Function 67 

Add Relay/System Features 

See page 27 

Function 68 

Delete All Relay Functions and 
System Options added by 
Function 67 
Door Ajar Trip Time 

See page 29 

Function 69 - 70 

Enable/Disable Enter Key 

See page 29 

Function 71 

Reserved 

-- 

Function 72 - 73 

Scheduled Enable/Disable  
Passage Mode 

See page 29 

Function 74 - 77 

Schedule Enable Group 1 - 4 

See page 29 

Function 78 

Schedule Enable All Groups 

See page 29 

Function 79 - 82 

Schedule Disable Group 1 - 4 

See page 29 

Function 83 

Schedule Disable All Groups 

See page 29 

Function 84 - 87 

Quick Schedules - Enable Group 

See page 30 

Function 88 

Passage Mode  

(Open Time Window) 

See page 30 

Function 89 

Passage Mode  

(Close Time Window) 

See page 30 

Function 90 

Relay Activation  

(Open Time Window) 

See page 31 

Function 91 

Relay Activation  

(Close Time Window) 

See page 31 

Function 92 

Enable Group 4  

(Open Time Window) 

See page 32 

Function 93 

Enable Group 4  

(Close Time Window) 

See page 32 

Function 95 - 98 

Reserved 

-- 

Function 99 

Clear All Lock Programming 

See page 32 

Function 94 

Disable Radio

 

See page 32 

Summary of Contents for Wireless Trilogy PDL6200

Page 1: ...security professionals only Publicly traded on NASDAQ Symbol NSSC ALARM LOCK 2016 Wireless Trilogy PDL6200 PDL8200 With Door Monitoring PDL8200 includes 13 56MHz Smart Card Support Programming Instructions PROXIMITY KEYFOB DL WINDOWS PROGRAMMING SOFTWARE AL IME USB GATEWAY MODULE AL IM2 SERIES GATEWAY MODULES AL IM2 80211 AL IME2 AL IME2POE PROXIMITY CARD 13 56MHZ SMART CARD PDL8200 ONLY AL IM2 PI...

Page 2: ...eferring to both models the word lock will here after be used unless otherwise noted is designed to allow all features to be programmed either at the keypad or through its radio link to a DL Windows equipped computer For example Audit Log Data may be transmitted through the radio link back to the DL Windows computer The PDL series features a real time clock calendar that automatically adjusts for ...

Page 3: ... ProxCards and ProxKey Keyfobs both function identically ProxKey Keyfobs can be substituted for all references to the ProxCard in this manual PDL8200 features a proximity reader that reads 13 56MHz smart cards exclusively page 2 User Features 5000 Users see pages 15 16 19 6 Pre defined Administration User Levels including Master Installer Manager Supervisor and Basic User Codes page 9 User Code Le...

Page 4: ... a computer network such as a LAN or corporate Intranet A Windows PC connected to this network can control and program all Networx series door locks by the use of the DL Windows software see OI382 and OI383 With access rights to the software one computer or several can control the software and consequently can control the devices in the system Note See below for an explanation of VERSION 2 Several...

Page 5: ...form diagnostic testing of existing Gateway radio signals within your installation environment Using the various available Modes the AL NSM can measure radio noise levels calculate overall signal quality discover Networx locks not yet assigned to Gateways and even send a locate signal causing all unassigned locks to beep The AL NSM can be used with an existing Gateway and the Gateway Signal Test M...

Page 6: ... you want to make changes to the lock program you enter Program Mode When you finish programming and wish to put the lock into use you exit Program Mode to enter Normal Mode You can enter Program Mode using the keypad by pressing the Master Code of the lock that was set at the factory then wait for the green light and press until multiple beeps are heard The Master Code is basically a secret 6 dig...

Page 7: ...mming tasks a User is allowed to perform The higher the Level the more pro gramming tasks the User is allowed with Master allowing ALL tasks Note Since the Programming Level is closely associated with the type of User and their abilities a User who holds a certain Programming Level is sometimes referred to by their User Type For example PDL series locks can hold up to 5000 Users in its programming...

Page 8: ...ssage to indefinitely unlock all doors press 123 to issue Return to Normal return ing all doors to normal non emergency operation In addition emergency commands may be sent via an RR 4BKEYFOB Note 3 chirps sound after each emergency com mand entry See page 11 and the DL Windows User Guide OI383 Emergency Commands for more information Note DL Windows does not need to be running to allow these Emerg...

Page 9: ...g Level as follows Master Always associated with User number 1 Is al ways enabled and can program all functions Abbreviated as Programming Level M Installer Always associated with Users 2 and 3 Can pro gram all functions except changing the Master Code Abbreviated as Programming Level 4 Manager Always associated with Users 4 5 and 6 Can program all functions except functions relating to lock confi...

Page 10: ...ogramming Key Sequence Programming Information General Program Mode Information If a wrong key is pressed during code entry press the key until the error sound is heard 7 short beeps this will clear the entry Re enter the key sequence again All program sequences are followed by the key 2 short beeps indicate a successful program sequence Enabling Disabling Users By User Number 3 Disable User 3 _ _...

Page 11: ...se When disabled The lock WILL NOT accept nor adhere to Emergency Com mands that disseminate from another lock or from DL Windows CAUTION Dis abling un checking this feature could be of great consequence for the safe ad ministration of your Networx system Activating Global Emergency Commands Keypad initiates Global Emergency Commands When enabled checked if an Emergency Command is initi ated from ...

Page 12: ...e Disabled During Lockdown is enabled checked for a specific lock and when the Networx system is in an Emergency Lockdown state Basic Users Users 12 are denied the ability to unlock the physical lock User Codes proximity credentials for these Basic Users are ignored The User Codes proximity credentials added to Administrative Users Users 1 through 11 as well as all Emergency Users remain enabled r...

Page 13: ...paired before a lock is enrolled into a Networx system However to allow for lock discovery the lock must be defaulted and re initialized see ERASE ALL PROGRAMMING on page 14 clearing all previously programmed Users and or paired Wireless Remote Releases Pairing Wireless Remote Release Buttons Refer to the programming instructions included with the model RR 1BUTTON Wireless Remote Release Button se...

Page 14: ...2 With battery power disconnected press and hold down for 10 seconds to ensure discharge of all capacitors 3 Re install the battery pack lock will sound 3 short beeps If beeps are not heard then restart at step 1 4 Within 5 seconds after hearing the 3 short beeps press and hold until the lock begins to beep then release 5 A series of 5 RED LED and 5 beeps will be heard followed by 10 seconds of si...

Page 15: ...ode to be 664433 Press 1 664433 664433 Now that the Master Code has been changed there is no need to change it again unless you want to Since you are still in Program Mode you can now proceed directly below and program various functions Note Programming any Function such as setting the clock follows a consistent 5 step pattern 1 Enter Program Mode 2 Press Function 3 Press and enter data 4 Press to...

Page 16: ...ity cre dential 3 Lock will beep continuously Place a new proximity credential in front of the reader under the lock keypad When the lock beeps three times the credential has been enrolled 4 Press to end the process To return to normal operation exit Program Mode see below Example You wish to enroll two proximity credentials for User 14 and User 15 respectively Press 2 1 4 and place the first cred...

Page 17: ...Code are both required for access 1 Enter the User Code for the User Number programmed for High Security Access The sounder will beep slowly for up to 10 seconds 2 Present the proximity card programmed for the same User Number User may enter User Code or present the proximity card in either order to open the lock The sounder will beep for up to 10 seconds waiting for the User to enter User Code or...

Page 18: ...tion 47 Timed Passage Mode See page 24 Programming Functions Overview Function 48 Enable Passage Mode See page 25 Function 49 Disable Passage Mode See page 25 Function 50 Return Lock to Normal Passage Mode Schedule See page 25 Function 51 Passage Mode Configuration See page 25 Function 52 54 Pass Time See page 25 Function 55 Reserved Function 56 Reserved Function 57 Reserved Function 58 Reserved F...

Page 19: ...gh the door 1 New Master Code User Number 1 1 _ _ _ _ _ _ _ _ _ _ _ _ New Master Code Confirm New Master Code 2 Adding and Deleting User Codes and or Proximity Cards for User Numbers 2 5000 2 _ _ _ _ _ _ _ _ _ _ User Number User Code Master Code must be 6 digits only Master Code is Keypad Code Access only Factory Default 123456 See Lock Design Overview on page 6 for more information about Master C...

Page 20: ...rk day by entering Program Mode and pressing 5 1157 008 NOTE Up to 4 Timeout Functions may be pending at any one time An error beep will sound when attempting to program more than 4 Timeout Functions 2 Service Code is a One Time Only Code Once it is used it is disabled until enabled again NOTE User Number 297 is used to reset Service Code Use See Terminology Used in this Manual on page 8 for more ...

Page 21: ...remain 3 13 Clear All Timeout Functions This Function enabled through keypad only CLEAR FUNCTIONS Group Enable Disable Enter the functions below to Enable Disable Groups Functions 14 23 will each override existing scheduled events Therefore Functions 14 23 are temporary take effect im mediately and are always overridden by future scheduled events that already exist within the lock programming 2 GR...

Page 22: ... Association As per the chart on page 9 the lock s default programming from the factory associates certain User Numbers with certain Groups To override these default Group associations Function 35 manually associates or disassociates a selected User with a selected Group During programming Groups not selected are then disassociated from the User Function 35 is helpful when the number of Users you ...

Page 23: ...nd ends at 2AM on the programmed date Enter 4 1 0 0 0 to disable DST All locks leave the factory with DST enabled and pre programmed to the following start and end dates for the USA beginning 2007 Default DST Start Date March Week 2 Sunday Second Sunday in March Default DST End Date November Week 1 Sunday First Sunday in November To program the DST start date using the keypad press 4 1 M M W D whe...

Page 24: ...nds Note Repeated use of these Functions are not cumulative this means for exam ple if the clock has already been set to speed up 10 seconds per day and then is found to need an additional 10 seconds then program 20 seconds using Function 43 Example 1 Clock is losing 13 seconds every day enter 4 3 1 3 This example assumes that the Clock Adjust setting was at the factory default of zero Example 2 C...

Page 25: ...r proximity credential presented When the Pass Time expires the lock will re lock automati cally Use the functions below to change the Pass Time to 3 10 or 15 seconds The Pass Time is defaulted to 3 seconds Pass Time 4 53 Set Pass Time to 10 Sec 54 Set Pass Time to 15 Sec PASS TIME See Scheduled functions 72 and 73 for Scheduled Passage Mode NOTE 51 Passage Mode Configuration 5 1 _ Mode Mode 1 Nor...

Page 26: ...ion about the Ambush Function 3 AMBUSH 6 0 _ Number of Attempts 6 1 _ _ Lockout Time 62 63 Reserved Programming Functions cont d 55 59 Reserved 6 4 64 Disable Remote Input Wire a Normally Open Contact to Wires White White Momentarily close switch to unlock door to allow person to pass through door Enter the functions below to Disable Enable the Remote Input Changes made with Function 64 or 65 are ...

Page 27: ...an the allowed Door Ajar Trip Time programmed at Function 68 the relay will engage for 2 seconds See Door Ajar in glossary 14 Activate Relay On Forced Door If the Door Position Contacts detect the door was opened without first a valid credential unlocking the lock or the door was opened without first the inside lever turned to activate the Lever Monitor Switch the relay will engage for 2 seconds S...

Page 28: ...ide Emergency Indicator Requires inside housing with light bar Pulses inside red LED while in Emergency Note Enabling this option deletes all other relay outputs 45 Activate Local Emergency Keypad initiates Local Emergency Commands Default ON Initiating an Emergency command directly from the lock s keypad places only that lock into an Emergency state the Emergency command is not sent to other lock...

Page 29: ... _ _ Day Time 73 Schedule Disable Passage Mode Lock 7 3 _ _ _ _ _ Day Time When this Function is enabled the User must press after any valid User Code entry Therefore this Function allows User Codes to be subsets of other User Codes Examples 1 2 3 can be a valid user code 1 2 3 4 can be a valid user code within the same lock 1 2 3 4 5 6 Hold for Master User Code to enter Program Mode Enter Key 4 P...

Page 30: ...7 for Saturday 8 for Monday to Friday 9 for Saturday and Sunday and 0 for all days of week Enter time of day in 24 hour format for example for 2 15 PM enter 14 15 Scheduled Passage Mode Group 1 Activated 89 Passage Mode Close Time Window This Function enabled through keypad only 8 9 _ _ _ _ _ Day Time SCHEDULES GROUP 1 ACTIVATED 3 For your convenience your lock comes pre programmed with Quick Sche...

Page 31: ...or Thursday 6 for Friday 7 for Saturday 8 for Monday to Friday 9 for Saturday and Sunday and 0 for all days of week Enter time of day in 24 hour format for example for 2 15 PM enter 14 15 Scheduled Relay Activation Group 1 Activated 9 1 _ _ _ _ _ Day Time 91 Relay Activation Close Time Window SCHEDULES GROUP 1 ACTIVATED 3 NOTES 1 Group 1 Disarms a Burglary Control Panel will always disarm an alarm...

Page 32: ...or Monday to Friday 9 for Saturday and Sunday and 0 for all days of week Enter time of day in 24 hour format for example for 2 15 PM enter 14 15 3 Programming Functions cont d 93 Enable Group 4 Close Time Window This Function enabled through keypad only 9 3 _ _ _ _ _ Day Time Scheduled Group 4 Enable Group 1 Activated Disable Radio Signal 94 Disable Radio This Function enabled through keypad only ...

Page 33: ...disarm option See To Disarm a Burglary Control Panel on page 31 If a Group 1 User does not enter their User Code dur ing the specified window Functions 90 91 remain inactive Function 92 and 93 allow for a window of time to be created where if any Group 1 User Code is entered within the programmed window the User Codes in Group 4 will be enabled If a Group 1 User does not enter their User Code duri...

Page 34: ...edule function of the alarm panel Functions 92 93 Use Function 92 and 93 see page 32 to create a window of time where if any Group 1 User Code is entered within the programmed window Group 4 Users will be enabled 1 Enter Program Mode if not in already 2 Using Function 2 create User 4 with a User Code of 456789 Press 2 4 4 5 6 7 8 9 3 Because User 4 does not have a default Group association make Us...

Page 35: ...ate Relay on Door Ajar 14 Activate Relay onForcedDoor 24 One Time Accessfor Group 3 Users 25 Disable Sounder 26 5 sec Delayed Entry 27 15 sec Delayed Entry 28 45 sec Delayed Entry 29 Toggle Passage Mode 30 Forced UnlockFollows Remote Input 31 Follow Access Granted No Time Limit 32 Remote Input Disables Unit 33 Remote Input Puts Unit inPC Communication Mode 38 Lock responds to Global Emergency Comm...

Page 36: ...36 User Number 1 5000 User Code 3 6 digits User Name 1 2 3 4 Group Association For a complete list of user codes obtain a printout from the DL WINDOWS software Note ...

Page 37: ...unctions can be programmed For Day Enter 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday 8 Monday through Friday 9 Saturday and Sunday 0 All days of the week Enter time of day in 24 hour format 00 00 23 59 Time Function Name ...

Page 38: ... of num bers entered via the keypad buttons that have been programmed in the lock and identified by the lock as a User Code CREDENTIAL A generic word used to indicate User Code a proximity card proximity keyfob such as a ProxKey keyfob a hardwired Remote Input mo mentary contact a Wireless Remote Release or any future device or design that allows the lock to unlock allowing passage through the doo...

Page 39: ...d LEVEL ABILITY Predefined User types such as Master Installer Manager and Supervisor have specific abilities to program and or control the lock LOCKOUT ATTEMPTS A specified number of invalid User Code entries 1 9 that will disable the keypad for a predefined period of time 1 60 seconds LOCKOUT TIME A predefined time 1 60 seconds that the lock will stop accepting User Codes after a specified numbe...

Page 40: ...olvents or other chemi cals This warranty contains the entire warranty It is the sole warranty and any prior agreements or representations whether oral or written are either merged herein or are expressly cancelled ALARM LOCK neither assumes nor authorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warran ty or liability concerning its produc...

Reviews: