To Disarm a Burglary Control Panel
(for locks equipped with an internal relay)
90. Relay Activation
(Open Time Window)
; 9 0 ;
[ _ ]
;
[ _ _ _ _ ]
:
(Day)
(Time)
Functions 90 and 91 allow you to set up a window of time where if any
Group 1
User Code is entered within this window, the
relay (where equipped) will be activated for 2 seconds. This relay can be used with a Control Panel that has a key switch
disarm option. For additional information, see "Group 1 Activated Features" on page 33. This function only available for
locks with an internal relay.
Also program relay option 6 using Function 67 (
; 6 7 ; 6 :
).
For
day
enter: 1 for Sunday, 2 for Monday, 3 for Tuesday, 4 for Wednesday, 5 for Thursday, 6 for Friday, 7 for Saturday,
8 for Monday to Friday, 9 for Saturday and Sunday, and 0 for all days of week.
Enter time of day in 24 hour format (for example, for 2:15 PM, enter 14:15).
Scheduled Relay Activation
(Group 1 Activated)
; 9 1 ;
[ _ ]
;
[ _ _ _ _ ]
:
(Day)
(Time)
91. Relay Activation
(Close Time Window)
SCHEDULES GROUP 1 ACTIVATED
3
NOTES
1.
Group 1 Disarms a Burglary Control
Panel
will always disarm an alarm
system. Arming should be performed
by other means (such as Alarm Panel
Keypad/Schedule).
2.
Use a qualified electrical/alarm
specialist to review your current alarm
system and add additional components
as needed (such as a relay, wire,
resistors, connectors and/or diodes) and
re-program the operation of your alarm
system as needed.
Programming Functions (cont'd)
Alarm Panel with Switched Input for Toggled Arm/Disarm
Alarm Panel with Switched Input for Disarming