background image

2.

 

Remove the old battery from the tray. 

3.

 

Place the new battery in the tray with the positive side 
facing down. 

 

4.

 

With the LCD screen still facing up, slide the tray back into 
the logger. The LCD should display “HOBO” briefly after 
correctly installing the battery. 

 

WARNING:

 Do not cut open, incinerate, heat above 85°C 

(185°F), or recharge the lithium battery. The battery may 
explode if the logger is exposed to extreme heat or conditions 
that could damage or destroy the battery case. Do not dispose 
of the logger or battery in fire. Do not expose the contents of 
the battery to water. Dispose of the battery according to local 
regulations for lithium batteries. 

HOBOware provides the option of recording the current battery 
voltage at each logging interval, which is disabled by default. 
Recording battery life at each logging interval takes up memory 
and therefore reduces logging duration. It is recommended you 
only record battery voltage for diagnostic purposes. 

CR2032 battery being 
placed in the tray, 
positive side facing 
down 

 

 

 

 

Office: Jl. Radin Inten II No. 62 Duren Sawit, Jakarta 13440 - Indonesia
Workshop: Jl. Pahlawan Revolusi No. 22B, Jakarta 13430 - Indonesia
Phone: 021-8690 6777 (Hunting)

Fax: 021-8690 6777

Mobile: +62 816 1740 8925

Fax: 021-8690 6771

Summary of Contents for Hobo UX100-003

Page 1: ...0 to 95 RH non condensing Launch Readout 0 to 50 C 32 to 122 F per USB specification Logging Rate 1 second to 18 hours 12 minutes 15 seconds Logging Modes Fixed interval normal burst or statistics Mem...

Page 2: ...logger is equipped with an LCD screen that displays details about the current status This example shows all symbols illuminated on the LCD screen followed by definitions of each symbol in the table b...

Page 3: ...Select Turn LCD off when setting up the logger as described in the next section When this option is enabled you can still temporarily view the LCD screen by pushing the Start Stop button for 1 second...

Page 4: ...and restart the logger with the Start Stop button 9 Choose whether to keep the LCD on or off By default the LCD will always remain on while logging If you select the Turn LCD off checkbox the LCD wil...

Page 5: ...ecord data every 10 seconds until the temperature falls back below the high limit or 85 F in this case At that time logging then resumes every 5 minutes at the normal logging interval Similarly if the...

Page 6: ...H data logged every 5 minutes plus eight maximum minimum average and standard deviation series four for temperature and four for RH with values calculated and logged every 5 minutes based on the 30 se...

Page 7: ...et HUM UPS 500 To replace the sensor 1 Use a screwdriver to pop out the louvered door in the logger case 2 Use needle nose pliers to remove the RH sensor from the board inside the logger case and disc...

Page 8: ...fire Do not expose the contents of the battery to water Dispose of the battery according to local regulations for lithium batteries HOBOware provides the option of recording the current battery volta...