WARNING:

 Do not cut open, incinerate, heat above 85°C 

(185°F), or recharge the lithium battery. The battery may 
explode if the logger is exposed to extreme heat or conditions 
that could damage or destroy the battery case. Do not dispose 
of the logger or battery in fire. Do not expose the contents of 
the battery to water. Dispose of the battery according to local 
regulations for lithium batteries. 

HOBOware provides the option of recording the current battery 
voltage at each logging interval, which is disabled by default. 
Recording battery life at each logging interval takes up memory 
and therefore reduces logging duration. It is recommended you 
only record battery voltage for diagnostic purposes. Even with 
the channel disabled, a bad battery event will still be recorded. 

 

 

 

 

Office: Jl. Radin Inten II No. 62 Duren Sawit, Jakarta 13440 - Indonesia
Workshop: Jl. Pahlawan Revolusi No. 22B, Jakarta 13430 - Indonesia
Phone: 021-8690 6777 (Hunting)

Fax: 021-8690 6777

Mobile: +62 816 1740 8925

Fax: 021-8690 6771

Summary of Contents for Onset HOBO UX100-001

Page 1: ...r statistics Memory Modes Wrap when full or stop when full Start Modes Immediate push button date time or next interval Stop Modes When memory full push button or date time Restart Mode Push button Time Accuracy 1 minute per month at 25 C 77 F see Plot B Battery Life 1 year typical with logging rate of 1 minute and sampling interval of 15 seconds or greater Battery Type One 3V CR2032 lithium batte...

Page 2: ...itely with newest data overwriting the oldest data When first launched all five segments in the memory bar will be empty In this example the memory is full all five segments are filled in and new data is now overwriting the oldest data This will continue until the logger is stopped or the battery runs out The logger is currently logging A sensor reading is above or below the high or low alarm that...

Page 3: ... In Normal mode data will always be recorded at the regular logging interval set in the previous step This is the default setting Burst In Burst mode logging will occur at a different interval when a specified condition is met See Burst Logging for more information Statistics In Statistics mode maximum minimum average and standard deviation statistics are calculated for the temperature during logg...

Page 4: ...y on the LCD screen Note that the alarm limits are only checked when the logger s LCD screen refreshes every 15 seconds The actual values for the high and low alarm limits are set to the closest value supported by the logger For example the closest value to 85 F that the UX100 series logger can record is 84 990 F and the closest value to 32 F is 32 043 F In addition alarms can trip or clear when t...

Page 5: ...or 9 22 in this case If burst logging had not occurred the next data point would have been at 9 15 A New Interval event will appear on the plot if you select events for plotting in the Plot Setup window each time the logger enters or exits burst logging mode Statistics Statistics is a logging mode in which the logger calculates maximum minimum average and standard deviation statistics during loggi...

Page 6: ...to mount it a wall or other flat surface Use the double sided tape to affix the logger to a surface Insert the hook and loop strap through the mounting loops on both sides of the logger to mount it to a curved surface such as a pipe or tubing Protecting the Logger The logger is designed for indoor use and can be permanently damaged by corrosion if it gets wet Protect it from condensation If the me...

Page 7: ...HOBOware provides the option of recording the current battery voltage at each logging interval which is disabled by default Recording battery life at each logging interval takes up memory and therefore reduces logging duration It is recommended you only record battery voltage for diagnostic purposes Even with the channel disabled a bad battery event will still be recorded Office Jl Radin Inten II ...

Reviews: