17

 

 

 

 

 

 

 

 

Caution

1.Input protection: The temperature  jack carried
   a maximum voltage of 24 volts DC or  AC .
2.Temperature jacks: Design for the insertion of a
   standard small thermocouple jacks, which has a
   center spacing of 7.9mm between the two 
   prongs.
3.Please DO NOT placed inside a microwave for 
   temperature testing.
4.A correct thermocouple slot should be chosen 
   when operating the temperature gauge.
5.Please DO NOT attempt to use a temperature 
   gauge that is not working properly, for this may
   result in physical harms, send for repair service 
   at once.
6.Please DO NOT attempt to operate the
   temperature gauge in the around sites where 
   explosive gases, vapor or dust particles are 
   present.
7.Please refrain from subject the paired
   thermocouple or the grounding between the 
   thermocouples to a voltage exceeding what has
   been marked on the unit.
8.When gauge occur crashed , please take one 
    battery out for above one minute. Then place
    the battery back and restart the gauge.   
   

C

YC-747UD

PC

  TM-7XX series thermometer
          K/J/T/E/R/S/N Types
               Data Logger
              Users Manual 

Summary of Contents for TM-7 Series

Page 1: ...ts Introduction Features General specifications Electrical specifications Operation Names of parts Battery replacement Caution 1 2 3 4 5 6 16 17 YC 747UD PC TM 7XX series thermometer K J T E R S N Typ...

Page 2: ...ed into 48 modes refer to the table below for a concise summary of subtle distinctions in their designed functions 2 1 The maximum displays for four temp values 2 Resolution 0 1 0 1 1 1 3 Swift respon...

Page 3: ...ture and Humidity 20 60 4 140 0 80 RH 11 Dimension 164x76x32mm LxWxH 12 Weight Approx 415g include batteries 13 Accessories A DC 1 5V UM 4 4pcs B Housing 1pcs C K type thermocouple wire single channel...

Page 4: ...selection key Press the key to sequentially alternate the three temp unit of and K 3 HOLD The readout hold function key Press the HOLD key a HOLD icon will display on the LCD and the readout held in p...

Page 5: ...TYPE K T1 TYPE K 25 25 REL REL REL step1 press step2 press 0 0 original temp input temp Save25 T1 TYPE K T1 TYPE K 25 30 REL REL 0 0 5 0 30 25 5 8 Operation 7 CHAN every input temp value changed to m...

Page 6: ...d will flicker for the chosen type C To confirm it then press SHIFT key The type became to J type Operation 9 COUNT The count time setting function key The max count time is 99 hours and 59 minutes 10...

Page 7: ...T3 T3 T3 step1 step2 step3 step4 HOLD HOLD SHIFT SHIFT SHIFT 12 Operation press press press press T1 TYPE K SHIFT T1 TYPE K T1 TYPE K SHIFT T1 TYPE K 25 25 25 25 30 30 30 30 40 40 40 40 50 50 50 50 T2...

Page 8: ...he adjustable word Back to main display 14 Operation press press press press press T1 TYPE K SHIFT T1 TYPE K 25 12 01 12 01 12 01 25 30 3003 3003 3003 2004 2004 2004 30 40 40 50 50 T2 T2 T4 y y y T4 T...

Page 9: ...1 5V battery at once to ensure the test accuracy 2 Remove the battery cover by one screwdriver 3 Replace the old battery with four new 1 5V batteries and lock the battery cover 4 Prior to replacing t...

Page 10: ...a temperature gauge that is not working properly for this may result in physical harms send for repair service at once 6 Please DO NOT attempt to operate the temperature gauge in the around sites whe...

Page 11: ...canceled and the power off will be canceled too When the memory is filled the display will appeared ou word For Data Logger models 1 2 Operation press last number surplus space time date date year pr...

Page 12: ...Enter and show settlement value last time for the second time after For USB or Data Logger models T1 TYPE K 25 30 40 50 T2 T4 T3 SHIFT SHIFT A A 4 6 carry out the record interval setting The biggest s...

Page 13: ...NTV PC INTV PC INTV back to main display The flashing number represents adjustable number SHIFT SHIFT SHIFT SHIFT A A A A 7 m s m s m s Office Jl Radin Inten II No 62 Duren Sawit Jakarta 13440 Indones...

Reviews: