background image

YC -7 47 UD

PC

Names Of Parts

 

5

1.LCD display

2.Function control key

3.Thermocouple input jack

4.Battery cover

5.PC input jack

6.Shift button

7.Power button

1

3

4

5

6

7

2

6

Operation

   

   

   

   

1.     :Power ON/OFF key.
         Press the power button to turn the power
         ON or OFF.

2. 

C / F/

K: The temperature Unit selection key.

               Press the key to sequentially alternate
               the three temp. unit of     ,    and K.

3.HOLD:The readout hold function key.
               Press the "HOLD"key, a "HOLD" icon
               will display on the LCD and the readout
               held in; press the "HOLD" key once 
               more to cancel the "HOLD" function.

4.MAX/MIN/AVG:The maximum/minimum/
                                  average readout function key
   

  
  

 

 

T1

TYPE:K

T1

TYPE:K

T1

TYPE:K

T1

TYPE:K

MAX

MAX

AVG

MAX

AVG

MAX

AVG

MAX
AVG

25

25

25

25

 

 

 

 

MIN

MIN

MIN

MIN

MIN

AVG

step1

press

Step2

press

Step3
press

Step4

press

Summary of Contents for TM-7 Series

Page 1: ...ts Introduction Features General specifications Electrical specifications Operation Names of parts Battery replacement Caution 1 2 3 4 5 6 16 17 YC 747UD PC TM 7XX series thermometer K J T E R S N Typ...

Page 2: ...ed into 48 modes refer to the table below for a concise summary of subtle distinctions in their designed functions 2 1 The maximum displays for four temp values 2 Resolution 0 1 0 1 1 1 3 Swift respon...

Page 3: ...ture and Humidity 20 60 4 140 0 80 RH 11 Dimension 164x76x32mm LxWxH 12 Weight Approx 415g include batteries 13 Accessories A DC 1 5V UM 4 4pcs B Housing 1pcs C K type thermocouple wire single channel...

Page 4: ...selection key Press the key to sequentially alternate the three temp unit of and K 3 HOLD The readout hold function key Press the HOLD key a HOLD icon will display on the LCD and the readout held in p...

Page 5: ...TYPE K T1 TYPE K 25 25 REL REL REL step1 press step2 press 0 0 original temp input temp Save25 T1 TYPE K T1 TYPE K 25 30 REL REL 0 0 5 0 30 25 5 8 Operation 7 CHAN every input temp value changed to m...

Page 6: ...d will flicker for the chosen type C To confirm it then press SHIFT key The type became to J type Operation 9 COUNT The count time setting function key The max count time is 99 hours and 59 minutes 10...

Page 7: ...T3 T3 T3 step1 step2 step3 step4 HOLD HOLD SHIFT SHIFT SHIFT 12 Operation press press press press T1 TYPE K SHIFT T1 TYPE K T1 TYPE K SHIFT T1 TYPE K 25 25 25 25 30 30 30 30 40 40 40 40 50 50 50 50 T2...

Page 8: ...he adjustable word Back to main display 14 Operation press press press press press T1 TYPE K SHIFT T1 TYPE K 25 12 01 12 01 12 01 25 30 3003 3003 3003 2004 2004 2004 30 40 40 50 50 T2 T2 T4 y y y T4 T...

Page 9: ...1 5V battery at once to ensure the test accuracy 2 Remove the battery cover by one screwdriver 3 Replace the old battery with four new 1 5V batteries and lock the battery cover 4 Prior to replacing t...

Page 10: ...a temperature gauge that is not working properly for this may result in physical harms send for repair service at once 6 Please DO NOT attempt to operate the temperature gauge in the around sites whe...

Page 11: ...canceled and the power off will be canceled too When the memory is filled the display will appeared ou word For Data Logger models 1 2 Operation press last number surplus space time date date year pr...

Page 12: ...Enter and show settlement value last time for the second time after For USB or Data Logger models T1 TYPE K 25 30 40 50 T2 T4 T3 SHIFT SHIFT A A 4 6 carry out the record interval setting The biggest s...

Page 13: ...NTV PC INTV PC INTV back to main display The flashing number represents adjustable number SHIFT SHIFT SHIFT SHIFT A A A A 7 m s m s m s Office Jl Radin Inten II No 62 Duren Sawit Jakarta 13440 Indones...

Reviews: