2. Preparation for Installation
100
Item
Model name
EPU-A
EPU-B
Maximum heat
emission
#3
1,534 kJ/h
1,008 kJ/h
#1: Excluding the dimensions of connectors and handles.
#2: Weight of the unit with maximum number of power supply modules. The weight of
cables and rack mounting brackets are excluded.
#3: Heat emission of the Switch only.
2.2.2 Environmental conditions
The environmental conditions of the Switch are listed below.
Table 2-10
Environmental conditions (AC models, DC models, AC (PoE) models, and
EPU models)
Item
Requirement
Device
EPU
AC model
DC model
AC (PoE)
model
EPU-A
EPU-B
Noise
#1
45 dB or less
50 dB or less
#2
45 dB or less
50 dB or less
#2
Vibration
2.45 m/s
2
or less
Dust
0.15 mg/m3 or less
#3
Temperatu
re
Operating
0 to 40 deg. C (23 to 28 deg. C
recommended)
#4
0 to 40 deg. C (23 to 28 deg. C
recommended)
Not
operating
-10 to 43 deg. C
Storage
and
transportati
on
-25 to 65 deg. C
Humidity
#5
Operating
10 to 85% (45 to 55% recommended)
Not
operating
8 to 85%
Storage
and
transportati
on
5 to 85%
#1: Measured value according to ISO 7779.
#2: When PoE supply is turned off.
Summary of Contents for AX2400S series
Page 3: ...Copyright Copyright C 2005 2011 ALAXALA Networks Corporation All rights reserved ...
Page 4: ......
Page 6: ...Preface II Find description from the AX2400S series manuals ...
Page 7: ...Preface III Find description from the AX3640S and AX3630S series manuals ...
Page 10: ...Preface VI ...
Page 14: ...Contents iv ...
Page 160: ...3 Preparation of Interface Cables and Terminals 130 ...