6. Web Authentication
181
icons (when page images, messages, and icons to be registered are stored in the
k-html
directory):
# ls -l k-html
-rwxr-xr-x operator users 1108 Dec 6 09:59 login.html
-rwxr-xr-x operator users 1302 Dec 6 09:59 loginNG.html
-rwxr-xr-x operator users 1300 Dec 6 09:59 loginOK.html
-rwxr-xr-x operator users 843 Dec 6 09:59 logout.html
-rwxr-xr-x operator users 869 Dec 6 09:59 logoutNG.html
-rwxr-xr-x operator users 992 Dec 6 09:59 logoutOK.html
-rwxr-xr-x operator users 109 Dec 6 09:59 webauth.msg
-rwxr-xr-x operator users 199 Dec 6 09:59 favicon.ico
-rwxr-xr-x operator users 20045 Dec 6 09:59 aaa.gif
# set web-authentication html-files k-html
Would you wish to install new html-files ? (y/n):y
executing...
Install complete.
Display items
None
Impact on communication
None
Response messages
Table 6-26:
List of response messages for the set web-authentication html-files command
Notes
•
This command does not check the contents of the HTML files. If the contents of the specified
file are incorrect, login and logout operations for Web authentication might not be possible.
•
This command can be executed regardless of whether or not the configuration command for
Web authentication has been set.
•
If this command is executed during dual operation, page images, messages, and icons are
registered automatically in the standby system. If you use the
synchronize
command to
synchronize the information between the active and standby systems, the information will
also be applied to the standby system.
•
Page images, messages, and icons registered by using this command are retained when Web
authentication is performed, the Web server is restarted, the Switch is restarted, and a switch
Message
Description
Can't execute.
The command could not be executed. Re-execute the command.
Can't execute this command in standby system.
This command cannot be executed on a standby system.
Can't put a sub directory in the directory.
The specified directory contains a subdirectory.
Can't specify "/config/wa/htdocs" in this command.
The
/config/wa/htdocs
directory cannot be specified.
Directory size over.
The capacity of the specified directory exceeds the limit (1024
KB).
Installation on standby system failed (active system
succeeded).
Although registration on the active system succeeded,
registration on the standby system failed.
Install operation failed.
An attempt to register the file failed.
No login.html file in the directory.
There is no
login.html
file in the specified directory.
No such directory.
The specified directory does not exist.
Too many files.
The number of files exceeds the limit of 100.
Summary of Contents for AX6300S series
Page 4: ......
Page 10: ......
Page 16: ......
Page 24: ......
Page 25: ...9 PART 2 Filters Chapter 2 Filters show access filter clear access filter ...
Page 34: ......
Page 49: ...3 Access List Logging 33 Notes None ...
Page 80: ...4 QoS 64 Notes None ...
Page 112: ......
Page 148: ......
Page 202: ......
Page 242: ......
Page 264: ......
Page 294: ......
Page 304: ......
Page 332: ......
Page 377: ...12 VRRP 361 Notes None ...
Page 378: ......
Page 388: ...13 IEEE 802 3ah UDLD 372 file in advance if necessary ...
Page 390: ......
Page 406: ......
Page 436: ...15 CFM 420 Notes None ...
Page 440: ...15 CFM 424 Notes None ...
Page 466: ...16 SNMP 450 appears and the MIB cannot be acquired ...
Page 483: ...467 Chapter 17 sFlow show sflow clear sflow statistics restart sflow dump sflow ...
Page 490: ......
Page 497: ...18 LLDP 481 Notes None ...
Page 520: ......